1.
Vertical Airflow Direction
•
The louver swings up and down as shown above.
•
The louver does not swing when the Indoor Fan stops
during operation at the upper limit.
Heating Mode
•
When the intake air temp. reaches 38°C (100.4°F), the
louver is changed from upper to lower limit. When the
intake air temp falls to 35°C (95°F), the louver is
changed from lower to upper limit.
2.
Horizontal Airflow Direction
•
The louver can be selected between 14° - 36° (as
shown above) when pressing Manual Airflow Direction
Selection Button.
•
The louver can be selected between 0° - 61° (as shown
above) when pressing Manual Airflow Direction
Selection Button.
8.9. Airflow Direction Control
Cooling, Ion and Soft Dry Mode
•
The left and right airflow direction louvers can be adjusted manually.
30
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G