Seitenansicht 25
Quiet Operation Control
(For Heating Mode)
Purpose of this operation is to provide quite heating operation compare to normal operation.
When the Quiet Mode is set at the remote control, Quiet Mode LED illuminates, the sound level will be automatically
decreased 2 dB (Lo), decreased 3 dB (Hi, Me), against the present sound level operation.
Quiet setting of fan speed rpm refer to Indoor Fan Speed Control.
Manual Airflow Direction:-
Rpm control during Lo, Me & Hi Cool
Auto Airflow Direction:-
Rpm control depends on the piping air temperature sensor of Indoor heat exchanger
Quiet Mode Operation will stop if:-
Quiet mode button is pressed again.
Stopped by ON/OFF switch.
Timer OFF activates.
Powerful mode button is pressed.