Panasonic CS-A9CKPG Bedienungsanleitung Seite 19

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 82
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 18
Time Delay Safety Control
Starting Current Control
Anti-Freezing Control
Compressor Reverse Rotation Protection Control
Compressor Protection Control
Automatic Fan Speed Mode
8.2. Soft Dry Mode Operation
The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and
then Soft Dry operation will start.
During Soft Dry operation, the Indoor Fan will operate at Lo- speed.
The operation will be switched on and off for up to 10 minutes “ON” and 6 minutes “OFF”. Once Soft Dry operation is turned
off, it stops for 6 minutes.
Once the compressor stops, it will not start for 3 minutes during Cooling operation.
Same as Starting Current Control for Cooling Mode operation.
Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressor
stops.)
Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6 minutes waiting
is valid during compressor stops.)
Same as Compressor Protection Control for Cooling Mode Operation.
When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.
Fan speed rotates at Lo- speed.
Deodorizing Control.
19
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G
Seitenansicht 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 81 82

Kommentare zu diesen Handbüchern

Keine Kommentare