Panasonic CS-UW12GKE Spezifikationen Seite 5

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 65
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 4
OutdoorUnit
5
Anti-reverseProtection
Toprotectthecompressorfromreverse
rotationwhenpoweroffsuddenly.
OverloadProtector
60-secondsTestOperationControl
Oncethecompressorisactivated,itdoesnot
stopfor60seconds.Itstopsimmediatelywith
remotecontrolON/OFFbutton.
Anti-freezingoperationforoutdoorunit(during
HeatingModeOperationonly)
Temperatureofthecondenseristestedbysensor.
DeicingControl
OverloadProtectionControl
Whenthetemperatureofevaporator
reaches51,outdoorfanstops,andwill
restartwhenthetemperatureofevaporator
declinesto49.
Whenthetemperatureofevaporator
reaches65,compressorwillstop.
4-wayValveControl
IftheunitisstoppedduringHeating
Operation,the4-wayvalvewillremainin
heatingmodeoperationfor5minutes.
CS-UW9GKE/CU-UW9GKE/CS-UW12GKE/CU-UW12GKE
CU-UW9GKECU-UW12GKE
The2-stepOverloadProtectoristoprotect
thecompressorwhen
1)Temperatureofcompressorreaches
2)Hightemperatureorcurrententersintothe
compressor
150
Seitenansicht 4
1 2 3 4 5 6 7 8 9 10 ... 64 65

Kommentare zu diesen Handbüchern

Keine Kommentare