1. Turn off power.
Turn off power at the circuit breaker or remove fuses to the appliance branch circuit.
2. Connect the power cord.
Connect the power cord in accordance with all governing codes and ordinances.
■ Three-phase connection (380-415 V 3N~ 50 Hz / 380-415 V 2N~ 50 Hz)
Separate the L wires and connect them in accordance with the instructions
given in the following table and diagram:
Electrical cable Wire connection
KY-B925GL
: Yellow / Green
(Connect to the earth terminal)
N: Black, Cord No. 2 / 4 / 6
L: Black, Cord No. 1 / 3 / 5
(Connect to the live terminal)
KY-B915AL / KY-B915AB
: Yellow / Green
(Connect to the earth terminal)
N: Grey and Blue together
L: Black and Brown together
(Connect to the live terminal)
Electrical Work
Electrical Connections
■ Single-phase connection (220-240 V ~ 50 Hz)
Connect the wires in accordance with the instructions given in the following
table and diagram:
N
L
Electrical cable Wire connection
KY-B925GL
: Yellow / Green
(Connect to the earth terminal)
N: Black, Cord No. 2 / 4 / 6
L1: Black, Cord No. 1
L2: Black, Cord No. 3
L3: Black, Cord No. 5
(Connect to the live terminal)
KY-B915AL / KY-B915AB
: Yellow / Green
(Connect to the earth terminal)
N: Grey and Blue together
L1: Black
L2: Brown
(Connect to the live terminal)
L1
L2
N
N
L
L1
L2
L3