EN-50 EN-51
English
Dimensions of Countertop Cutout
Side View with an Oven
Flow of intake
and exhaust
Oven
When Installing Above an Oven
■ The appliance may only be installed over a Panasonic oven.
■ Allow for extra spaces for air circulation as shown below.
Dimensions
(measurement: mm)
R3 1
490
3
0
870
3
0
Building side wall
Countertop front
Min. 59
Building side wall
Building rear wall
Min.51
Min.600
Min.51
Min.51
Electrical Work
WARNING
Electrical work must be performed by a legally qualied electrician.
Min. 60
Min. 5 Min. 40
Oven
Electrical Requirements
Installation of the Earth Leakage Circuit Breaker
■ This appliance must be supplied with the proper voltage and frequency, and
connected to an individual, properly earthed branch circuit, protected by a
circuit breaker or fuse. (The rating plate is on the bottom of the appliance.)
■ This appliance is not tted with other means for disconnection from the supply
mains having a contact separation in all poles that provide full disconnection
under overvoltage category III conditions. Means for disconnection must be
incorporated in the xed wiring in accordance with the wiring rules.
■ Single-phase A.C. 220-240 V, 50 Hz electrical system must be used. (It is also
possible to use a three-phase electrical system.) If connecting to aluminium
wiring, use connectors approved for use with aluminium wiring.
■ Check with the local utilities for electrical codes applied in the area. Failure to
wire the appliance according to governing codes may result in a hazardous
condition.
■ After installation, show the customer where the breaker for the appliance is
located.
■ In accordance with the electrical wiring rules, incorporate the earth leakage
circuit breaker in the home electrical wire.
■ Follow the specication of the earth leakage circuit breaker as follows.
Rated current: 50 A (KY-B927GF / SL / GL), 40 A (KY-B917AF / AL / AB)
Rated sensitivity current: 30 mA