Panasonic KIT-XE7-LKE Datenblatt

Stöbern Sie online oder laden Sie Datenblatt nach Split-System-Klimaanlagen Panasonic KIT-XE7-LKE herunter. Panasonic KIT-XE7-LKE air conditioner Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 16
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
20
1) EER and COP classification is at 230 V in accordance with EU directive 2002/31/EC.
2) The annual consumption is calculated by multiplying the input power at 230 V by an avarage of 500 hours per year in cooling mode.
3) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body and 0,8 meters below the
unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
4) Add 70 mm for piping port.
5) When installing the outdoor unit at a higher position than the indoor unit.
GLOBAL REMARKS Rating conditions Cooling Heating
Inside air temperature 27ºC DB / 19ºC WB 20ºC DB
Outside air temperature 35ºC DB / 24ºC WB 7ºC DB / 6ºC WB
DB: Dry Bulb; WB: Wet Bulb
This model is not suitable to use in heating mode below -5ºC with continuous operation (24h operation).
Connectivity restriction: JKE units are not compatible with LKE units.
WALL MOUNTED ETHEREA // INVERTER+ // SILVER
NEW ETHEREA WITH ECO PATROL, MORE EFFICIENT, MORE COMFORT, MORE DESIGN, MORE HEALTHY AIR
Eco Patrol’s sensor technology uses factors such as speed, frequency and temperature to determine the human
activity level in the room for maximum comfort and maximum savings. With Eco Patrol, you can save up to 30%.
Furthermore, Etherea is more efficient than ever with 64% less consumption for the non Inverter model on
heat pump mode, and can reach 71% total savings when used with Eco Patrol. More efficiency for bigger
savings!
Etherea has an advanced air purifying system with the new Patrol Sensor to detect and eliminate
contaminants.
Etherea is also able to prevent rapid decreases in room humidity with the new mild dry cooling system which
increases comfort, especially when sleeping with the air conditioning running.
WALL MOUNTED ETHEREA // INVERTER+ // SILVER
Kit KIT-XE7-LKE KIT-XE9-LKE KIT-XE12-LKE KIT-XE15-LKE
Indoor CS-XE7LKEW CS-XE9LKEW CS-XE12LKEW CS-XE15LKEW
Outdoor CU-E7LKE CU-E9LKE CU-E12LKE CU-E15LKE
Cooling capacity
Nominal (Min - Max) kW 2.05 (0.70-2.40) 2.50 (0.80-3.00) 3.50 (0.80-4.00) 4.20 (0.80-5.00)
Nominal (Min - Max) kCal/h 1,760 (600-2,060) 2,150 (690-2,580) 3,010 (690-3,440) 3,610 (690-4,300)
EER
1)
Nominal (Min - Max) Energy Saving Classification
4.36 (4.12-4.14)
A
4.67 (4.57-4.11)
A
4.07 (4.32-3.54)
A
3.33 (4.10-3.18)
A
Power input Cooling Nominal (Min - Max) kW 0.47 (0.17-0.58) 0.535 (0.175-0.730) 0.860 (0.185-1.130) 1.26 (0.195-1.570)
Heating capacity
Nominal (Min - Max) kW 2.80 (0.70-4.00) 3.40 (0.80-5.00) 4.00 (0.80-6.00) 5.30 (0.80-6.80)
Nominal (Min - Max) kCal/h 2,410 (600-3,440) 2,920 (690-4,300) 3,440 (690-5,160) 4,560 (690-5850)
Heating capacity at -7°C Nominal kW 2.35 2.88 3.46 3.94
COP
1)
Nominal (Min - Max) Energy Saving Classification
4.41 (4.38-3.92)
A
4.63 (4.85-3.85)
A
4.21 (4.57-3.51)
A
3.68 (4.32-3.51)
A
Power input Heating Nominal (Min - Max) kW 0.635 (0.16-1.02) 0.735 (0.165-1.30) 0.950 (0.175-1.71) 1.44 (0.185-1.940)
Annual Energy Consumption
2)
kWh 235 268 430 630
Indoor unit
Air Volume Cooling / Heating m³/h 654 / 684 678 / 702 750 / 768 750 / 804
Moisture removal volume l/h 1.3 1.5 2.0 2.4
Sound pressure Level
3)
Cooling (Hi / Lo / S-Lo) dB(A)
37 / 24 / 20 39 / 25 / 20 42 / 28 / 20 43 / 31 / 25
Heating (Hi / Lo / S-Lo) dB(A) 38 / 25 / 20 40 / 27 / 20 42 / 33 / 20 43 / 35 / 29
Sound power Level
Cooling (Hi) dB 53 55 58 59
Heating (Hi) dB 54 56 58 59
Dimensions H x W x D mm 290 x 870 x 204 290 x 870 x 204 290 x 870 x 204 290 x 870 x 204
Net weight kg 9 9 9 9
Air purifier filter Patrol + E-ion Patrol + E-ion Patrol + E-ion Patrol + E-ion
Outdoor unit
Power source V 230 230 230 230
Connection mm² 4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5
Current Cooling Nominal A 2.2 2.5 3.9 5.7
Current Heating Nominal A 3.0 3.4 4.4 6.6
Max. current A 4.7 5.8 7.8 9.0
Air Volume Cooling / Heating m³/h 2,034 / 2,034 1,788 / 1,788 1,860 / 1,860 1,884 / 1,884
Sound pressure Level
3)
Cooling (Hi) dB(A) 45 46 48 49
Heating (Hi) dB(A) 46 47 50 51
Sound power Level
Cooling (Hi) dB 60 61 63 64
Heating (Hi) dB 61 62 65 66
Dimensions
4)
H x W x D mm 540 x 780 x 289 540 x 780 x 289 540 x 780 x 289 540 x 780 x 289
Net weight kg 33 34 34 34
Piping connections
Liquid pipe inch (mm) 1/4" (6.35) 1/4" (6.35) 1/4" (6.35) 1/4" (6.35)
Gas pipe inch (mm) 3/8" (9.52) 3/8" (9.52) 3/8" (9.52) 1/2" (12.70)
Refrigerant Loading R410A kg 0.830 0.950 0.980 1.01
Elevation difference (in/out)
5)
Maxm 15151515
Piping length Min / Max m 3-15 3-15 3-15 3-15
Piping length without refrigerant
increase
Max m 7.5 7.5 7.5 7.5
Additional gas g/m 20 20 20 20
Operating range
3)
Cooling Min / Max °C +5 / +43 +5 / +43 +5 / +43 +5 / +43
Heating Min / Max °C -5 / +24 -5 / +24 -5 / +24 -5 / +24
Maintains a Relative Humidity up to 10%
higher than cooling operation. Ideal when
sleeping with the air conditioner on.
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1

201) EER and COP classification is at 230 V in accordance with EU directive 2002/31/EC.2) The annual consumption is calculated by multiplying the inpu

Seite 2 - KIT-XE15-LKE

29DOMESTICNEW10CU-E7LKE-3CU-E9LKE-3CU-E12LKE-3KIT-XE7-LKE-3 // KIT-XE9-LKE-3 // KIT-XE12-LKE-3 // KIT-XE15-LKE-3 // KIT-E7-LKE-3 // KIT-E9-LKE-3 //KIT

Seite 3

30WALL MOUNTED RE TYPE // STANDARD INVERTERRE:Inverter models are powerful and efficient and are always there when you need them. Furthermore, with th

Seite 4 - KIT-XE18-LKE // KIT-XE21-LKE

31DOMESTICKIT-RE9-JKE-1 // KIT-RE12-JKE-1 // KIT-RE15-JKE-1 //KIT-RE18-JKE-1 // KIT-RE24-JKE-1HEALTHY AIR· New generation Alleru-buster anti allergic

Seite 5

32WALL MOUNTED TYPE // INVERTER+ // -15ºCComplete line-up of air purifying systems with high efficiency even at -15ºC! This wall-mounted air condition

Seite 6

33DOMESTICKIT-E9-HKEA // KIT-E12-HKEA // KIT-E15-HKEA // KIT-E18-HKEA // KIT-E21-HKEAHEALTHY AIR· Refreshing ion generator boosts well-being· Alleru

Seite 7

34OPTIONALWALL-MOUNTED TYPE // STANDARD HEAT PUMPPowerful heat pump non-Inverter air conditioning. A class efficiency for high savings.1) EER and COP

Seite 8

35DOMESTICKIT-PW9-GKE // KIT-PW12-GKE //KIT-PW18-GKE // KIT-PW24-JKEHEALTHY AIR· Soft dry operation mode· Odour-removing function· CZ-SA14P Alleru-b

Seite 9 - WALL MOUNTED // INVERTER+

21DOMESTICNEW10CU-E7LKECU-E9LKECU-E12LKECU-E15LKEKIT-XE7-LKE // KIT-XE9-LKE // KIT-XE12-LKE // KIT-XE15-LKEHEALTHY AIR· E-ion plus air purifying syst

Seite 10 - TECHNICAL FOCUS

22WALL MOUNTED ETHEREA // INVERTER+ // SILVERNEW ETHEREA WITH ECO PATROL, MORE EFFICIENT, MORE COMFORT, MORE DESIGN, MORE HEALTHY AIREco Patrol’s sens

Seite 11

23DOMESTICNEW10CU-E18LKECU-E21LKEKIT-XE18-LKE // KIT-XE21-LKEHEALTHY AIR· E-ion plus air purifying system· Patrol sensor to detect and eliminate con

Seite 12

24WALL MOUNTED ETHEREA // INVERTER+ // WHITENEW ETHEREA WITH ECO PATROL, MORE EFFICIENT, MORE COMFORT, MORE DESIGN, MORE HEALTHY AIREco Patrol’s senso

Seite 13

25DOMESTICNEW10CU-E7LKECU-E9LKECU-E12LKECU-E15LKEINCLUDED WITH THE INDOOR UNITKIT-E7-LKE // KIT-E9-LKE // KIT-E12-LKE // KIT-E15-LKEHEALTHY AIR· E-io

Seite 14 - KIT-E18-HKEA // KIT-E21-HKEA

26WALL MOUNTED ETHEREA // INVERTER+ // WHITENEW ETHEREA WITH ECO PATROL, MORE EFFICIENT, MORE COMFORT, MORE DESIGN, MORE HEALTHY AIREco Patrol’s senso

Seite 15

27DOMESTICNEW10CU-E18LKECU-E21LKECU-E24LKECU-E28LKEKIT-E18-LKE // KIT-E21-LKE // KIT-E24-LKE // KIT-E28-LKEHEALTHY AIR· E-ion plus air purifying syst

Seite 16 - KIT-PW18-GKE // KIT-PW24-JKE

28WALL MOUNTED // INVERTER+NEW ETHEREA WITH ECO PATROL, MORE EFFICIENT, MORE COMFORT, MORE DESIGN, MORE HEALTHY AIREco Patrol’s sensor technology uses

Kommentare zu diesen Handbüchern

Keine Kommentare