-8-
CONNECTION
Caution: Keep the POWER switch of the specified
monitor, Camera Extension Unit and Camera Drive
Unit in OFF position while making connections. If
the power of these units is ON during connections,
the camera does not function due to the built-in
protection circuit which protects it against wrong
connections.
• Basic System
Connect the coaxial cables between the camera
and CAMERA IN connector of the specified moni-
tor or Camera Drive Unit. The approximate maxi-
mum cable length is as follows:
Coaxial Maximum DC R/1000 ft. of
Cable Type Cable Lenth Inner Conductor
RG-59/U 200 m (660 ft) Less than 30 Ω
RG-6/U 500 m (1,650 ft) Less than 12 Ω
The maximum DC resistance between the camera
and these unit is 20 Ω.
Kommentare zu diesen Handbüchern