Step 6
Connect cables to the External I/O terminals, microphone/
line input connector, audio output connector and the
monitor out connector for adjustment. When connecting
these cables, hold the main body of the camera.
Microphone/line
input connector
Audio output connector
Monitor out
connector for
adjustment
External I/O terminals
Main
body
• External I/O terminals
Connect external devices.
When connecting an external device, remove 9 mm - 10 mm
{11/32 inches - 13/32 inches} of the outer jacket of the cable
and twist the cable core to prevent the short circuit first.
Specification of cable (wire): AWG #22 - #28,
Single core, twisted
IMPORTANT:
 • Donotconnect2wiresormoredirectlytoaterminal.
When it is necessary to connect 2 or more wires, use
a splitter.
 • Off, input, and output of the external I/O terminal 2
and 3 can be switched by configuring the setting.
Refer to the Operating Instructions on the provided
CD-ROM for further information about the EXT I/O
terminal 2 and 3 (ALARM IN2, 3) settings (“Off”,
“Alarm input”, “Alarm output” or “AUX output”).
 • ThedefaultofEXTI/Oterminalsis“Off”.When“Off”is
selected, it is possible to connect external devices as
well as the input setting.
 • WhenusingtheEXTI/Oterminalsastheoutputtermi-
nals, ensure they do not cause signal collision with
external signals.
<Ratings>
 •
ALARM IN1/ DAY/NIGHT IN, ALARM IN2, ALARM IN3
Input specification: No-voltage make contact input
(4 V - 5 V DC, internally pulled up)
OFF: Open or 4 V - 5 V DC
ON: Make contact with GND (required drive current:
1 mA or more)
 • ALARMOUT,AUXOUT
Output specification: Open collector output
(maximum applied voltage: 20 V DC)
Open: 4 V - 5 V DC by internal pull-up
Close: Output voltage 1 V DC or less
(maximum drive current: 50 mA)
• Microphone/line input cable
Connect a monaural mini plug (ø3.5 mm).
 • Inputimpedance:Approx.2kΩ(unbalanced)
 • Recommendedcablelength:
Less than 1 m {3.28 feet} (for microphone input)
Less than 10 m {32.8 feet} (for line input)
 •
Recommended microphone: Plug-in power type (option)
 • Supplyvoltage:2.5V±0.5V
 •
Recommendedsensitivityofmicrophone:–48dB±3dB
(0 dB=1 V/Pa,1 kHz)
 • Inputlevelforthelineinput:Approx.–10dBV
 • Recommendedplug:Ltype
IMPORTANT:
 •Connect/disconnecttheaudiocablesandturnonthe
power of the camera after turning off the power of the
audio output devices. Otherwise, loud noise may be
heard from the speaker.
• Audio output cable
Connect a stereo mini plug (ø3.5 mm) (Audio output is
monaural.). Use an external powered speaker.
 • Outputimpedance:Approx.600Ω(unbalanced)
 •
Recommended cable length: Less than 10 m {32.8 feet}
 • Outputlevel:–20dBV
 • Recommendedplug:Ltype(Astraighttypeplugmust
be 40 mm {1-9/16 inches} or less.)
Note:
 • Make sure that the stereomini plug is connected to
this cable. When a monaural mini plug is connected,
audio may not be heard.
When connecting a monaural speaker with amplifier,
use an optional conversion cable (mono-stereo).
• Monitor out connector for adjustment
Connect a monaural mini plug (ø3.5 mm) (only for check-
ing if images are displayed on the monitor).
 • Recommended plug: Straight type (Because of the
pin array difference, it is difficult to fit an L type plug
into this connector.)
IMPORTANT:
 •Themonitoroutconnectorforadjustmentisprovided
only for checking the adjustment of the angular field
of view on the video monitor when installing the cam-
era or when servicing.
It is not provided for recording/monitoring use.
 •Black bands may appear at the top and bottom or
right and left of the screen. (That does not affect the
adjustment because the angular field of view is not
changed.)
Approx. 9 mm - 10 mm
{11/32 inches - 13/32 inches}
Strip range
4 3 2 1
EXT I/O terminal 3
(ALARM IN3/AUX OUT (Auxiliary output))
EXT I/O terminal 2
(ALARM IN2/ALARM OUT)
GND
EXT I/O terminal 1
(ALARM IN1/ DAY/NIGHT IN)