Panasonic WV-ASC970 Betriebsanleitung Seite 72

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 79
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 71
72
REDUDANT section
This section assigns the RS232C Port for the redundant communication. The RS232C Port cannot be
shared between the redundant communication and serial alarm interface.
[REDUNDANT]
***{ The RS232Port can be used as redundant communication, }
***{ if Backup CPU is checked in the Admin Console. }
***{ If no check, the port can be used for serial alarm when }
***{ Admin Console set the RS232C Controller. }
***{ Note: }
***{ The RS232Port should not share the RS232C Controller }
***{ defined in the Admin Console. }
***{ The RS232Port starts with "0", while RS232C Controller }
***{ in the Admin Console starts with "1". }
***{Format:RS232Port=<port#> }
***{0=firstRS232CPortofyourserver }
***{1=secondRS232CPortofyourserver(ifexisting) }
***{2=thirdRS232CPortofyourserver(ifexisting) }
RS232Port=0
TIMELINE section
This section allow user to change some settings for the ASM970 Client Software Time-Line feature.
[TIMELINE]
***{ This section allow user to change polling frequency of }
***{ retrieving the DVR and alarm information for the ASM970 Client Software }
***{ Time-Line feature. }
***{Format:TimeLine=<Minutes>,<Days>,<Model> }
***{Minutes=FrequencytoretrievefromDVR(5-30min) }
***{Days=daystosaveonHD(1-9999) }
***{Mode=0-off }
***{1–on(default) }
TimeLine=10,7,1
***{ This section allow user to change delete timing }
***{ of saving DVR and alarm information in ASC970. }
***{Format:DeleteTime=<Hour>}
***{Hour=Timetodeletethesavinginformation(00:00–23:59) }
DeleteTime=02:00
Alive Monitoring section
This section allow user to change some settings for the Alive Monitoring feature.
[ALIVEMONITORING]
***{ This section allow user to change the number of alive monitoring}
***{ of devices(Camera and Recorder) at a time.}
***{Format:CamAliveMonitoringNum=<MaxNumber>}
***{MaxNumber=NumberofalivemonitoringatatimeforCamera(1-256)}
***{Format:RecAliveMonitoringNum=<MaxNumber>}
Seitenansicht 71
1 2 ... 67 68 69 70 71 72 73 74 75 76 77 78 79

Kommentare zu diesen Handbüchern

Keine Kommentare