User’s Manual LED UV Curing System Aicure SPOT Type UJ30/35 Series 2011.9 |panasonic-electric-works.net/sun
x Contents 1 Features of the ANUJ 3000/3500...1 2 Product components...
1 Features of the ANUJ 3000/3500 1 The ANUJ 3000/3500 is an UV curing device that quickly hardens UV resins (inks, adhesives, and coatings) via
Features of the ANUJ 3000/3500 2 The Universal design for easy operation Easy operation has been achieved by the product’s universal desi
2 Part names and functions 3 Controller AC adapter 100 V (AC) power cable for use in Japan only Instruction Manual Optional parts (sold
3 Part names and functions 4 Front of the controller UV sensor (option) Rear of the controller AC adapter
Part names and functions 5 Description Function Remark (1) EMISSION switch UV is irradiated and stopped by selected irradi
6 4 Installation Install and set up the product according to the following conditions. 4.1 Installation conditions 1) Ambient temp.: Con
Installation 7 ANUJ6428 ANUJ6428 ANUJ6428 ANUJ6428 (φ8mm)05001,0001,5002,0002,5003,0003,5004,000-5 -4 -3 -2 -1 0 1 2 3 4 5照射範囲(mm)UV強度(mW/cm2)WD=1
Installation 8 Cylindrical lens data (typical characteristics) Rod lens data (typical characteristics) Side-view lens data
9 5 Getting started After connecting the necessary cords, lastly plug in the power cord. This section describes the steps up to turning on t
LED product safety precautions ii LED Product Classification The light source of the LED head connected to this product is classified as 3B under
Getting started 10 Rear panel <Procedure> 1. Plug in the connection cable. 2. Connect the LED head to the connection cable. 3. Remove the pr
Getting started 11 5.3 Connecting the external control signals The external control connectors on the back of the controller (two blocks of
Getting started 12 5.4 Connecting the AC adapter Plug the connector of the supplied AC adapter into the AC adapter connector on the rear pan
13 6 Operation modes 6.1 Operation mode (default mode when power is turned on) Status check Displays in Operation mode Display Descriptions
Operation modes 14 How to operate the controller 1) Setting irradiation conditions Setting the irradiation intensity and irradiation time separat
Operation modes 15 3) Continuous irradiation Irradiation using the EMISSION switch of the controller TheTheTheThe displayeddisplayeddisplayedd
Operation modes 16 5) Display of head management information [Head temperature (°C or °F)]
Operation modes 17 6.2 UV measurement and Auto tuning mode It is possible to make UV measurements and Auto tunings. * To use this mode it is nec
Operation modes 18 2) Auto tuning (1) Switching to calibration mode 1. While in operation mode, press the UV CHK switch. 2. The intensity set
Operation modes 19 6.3 Default settings mode This mode is used for the units (°C/°F) for head temperature readings, for switchi
LED product safety precautions iii Laser products Preventive safety measures for users (summary) [from JIS “Safety of laser products”] Classif
Operation modes 20 6.4 Timing chart 1) Batch irradiation: Heads selected (*1) with CH1 through 4 operation button in front of the controller are p
Operation modes 21 ② Continuous (Con) batch irradiation
Operation modes 22 2) Individual irradiation When START 1~4 input on the backside of the controller is turned on, individual CH is irradiated. ・ P
Operation modes 23 *1) It is not possible to select a particular channel unless it has an LED head connected to it. *2) Conditions under which the
24 WarningWarningWarningWarning 7 External control 7.1 External input/output control External control connectors (12 pin × 2) MINI COMBICON Pl
External control 25 Output Specification ・Rated load voltage: 5 V DC to 28 V DC ・Max. load current: 100 mA (per 1 output) When 5 V internal voltage
External control 26 7.2 Serial communication control RS-232C terminal specifications (D-Sub 9-pin) D-sub 9-pin connector (male pins) (JAE: DE
External control 27 WarningWarningWarningWarning Commands and responses ・ Instructions sent to the controller are called commands. ・ Messages
External control 28 Control commands Support commands An instruction for the controller is called a “command,” while the message sent back from
External control 29 Data areas
LED product safety precautions iv Safety features This product is equipped with the following safety features, based on JIS C6802 “Safety of laser p
External control 30 7.3 Communications address map Address for reading (1 address = 16 bits)
External control 31
External control 32
External control 33
External control 34 Address for writing (“1 address = 16bit”) …New settings take effect when the address of the data setting is executed. (T
External control 35
External control 36
External control 37
External control 38 WRITE procedure ・Communication data is accepted at each address, and the accepted data will be confirmed by the execution of
External control 39 7.4 Setup tool application for UJ35 Operation from a PC ・Application can be downloaded from the web. ・Compatible with Wi
LED product safety precautions v Labels The LED irradiation warning labels (shown below specified by JIS C6802) shown below are attached to the L
External control 40 1. Open the Aicure UJ35 application 2. Select initial settings ・Select the port for UJ35 controller connection (default settin
External control 41 4. Using the operation setting screen [Settings 1] 1) Set UJ – Selects Type from 0 to 7 (does not switch CH selection).
External control 42 4) “Cumulative irradiation time (×100hrs)”… To set the cumulative irradiation time (*During setting “Cumulative irradiation tim
External control 43 2) “Replacement time (×100hrs)”… To set the LED replacement time (* While changing replacement time settings, “Replacement time
External control 44 6. Using the AUTO screen (only available in online mode) … Displays all UJ35 controller information in real time. … Enables ir
External control 45 7. Using the UV.CHK screen (only available in online mode). … Displays all UJ35 controller information in real time. … Enables
8 Warning indications 46 In the event of an error during irradiation, a warning will be displayed on the display panel of the controller (in operat
Warning indications 47 Error codes When an error occurs, the three-digit display will indicate the error code. Display Error name Error descri
9 Safety measures 48 9.1 Safety circuit Aicure UJ35 is equipped with a safety circuit, which functions as follows, in case of a malfunction or ac
10 Specifications 49 10.1 Outline of specifications Controller specifications Item ANUJ3000 ANUJ3500 No. of connected heads 1-4 heads UV s
Safety precautions vi The purpose of the following caution indications is to ensure the safe and correct use of this product, in order to protect us
Specifications 50 High-power head Item ANUJ6170・ANUJ6171 Spot diameter φ3mm φ4mm φ6mm φ8mm φ10mm Lenses Lens model ANUJ6423 ANUJ6424 ANUJ6426
11 Dimensions 51 High-power head Item ANUJ6160・ANUJ6161 Spot diameter φ3mm φ4mm φ6mm φ8mm φ10mm Lenses Lens model ANUJ6423 ANUJ6424 ANUJ6426
Specifications 52 UV sensor specifications Item ANUJ3800 High range 0 to 49.9 W/cm2 (min. reading 0.1 W/cm2) UV intensity measurement range Low r
11 Dimensions 53 Mounting bracket ANUJ6804 UV SENSOR ANUJ3800 LED head ANUJ6172/6162 Connection cable ANUJ6220 Standard lens
12 Option and spare parts list 54 1)Controller Name Description Product number UJ30 controller 4 head connection (incl. AC adapter) ANUJ300
Option and spare parts list 55 5)Options and spare parts Name Description Product number UV sensor Special UV sensor for UJ35 controller ANUJ3
12 Option and spare parts list 56 WarningWarningWarningWarning 12.2 How to replace the lens unit 1)Rotate the lens unit to attach it to the LE
13 Troubleshooting 57 Symptoms Checks/Remedies LED does not irradiate. Did you select the target channel for the product type? (When selected, t
Manual revision history 58 Manual No. Issued Revision Details ARCT1F510E 2010.05 Initial version ARCT1F510E-1 2010.10 2nd edition ARCT1F5
Please contact ... ASCT1F510E-2 Specifications are subject to change without notice. Printed in Japan
Precautions for use vii General precautions ・ Never connect any LED head, connection cable, AC adapter, or UV sensor to the main unit, other t
Precautions for use viii Setup ・ Check that the rubber feet of the product are always horizontally level. Never incline the product, or positi
Precautions for use ix ・ SELLER SPECIFICALLY DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR USE OR PURPOSE,
Kommentare zu diesen Handbüchern