Panasonic TH42PW6BX Betriebsanleitung

Stöbern Sie online oder laden Sie Betriebsanleitung nach Plasmafernseher Panasonic TH42PW6BX herunter. Panasonic TH42PW6BX Operating Instructions Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - TH-42PW6

®PLASMA DISPLAYR - STANDBYG POWER ONINPUTMENU+ENTER–VOL POWER /TQBC0563-1Before connecting, operating or adjusting this product, please read the

Seite 2 - Dear Panasonic Customer

10R - STANDBYG POWER ONINPUT MENU ENTER+-VOLTH-42PW6Basic ControlsStatus button1 Input label2 Aspect mode (see page 16)3 Off timerThe off timer indi

Seite 3 - Important Safety Notice

11PLASMA DISPLAYINPUTSURROUNDVOLNRPICTURESOUNDSET UPASPECTPICTUREPOS. /SIZEOFF TIMERPCMULTIPIPSWAP SELECT MOVEBasic ControlsSURROUND ButtonThe benefit

Seite 4 - Safety Precautions

12Power On/Off and input signal selectionPower On/OffRemote Control SensorPower IndicatorAC cord connectionConnect the plug to the Wall OutletPress th

Seite 5 - Cleaning and maintenance

13Select the input signalPress the INPUT button to select the input signal to beplayed back from the equipment which has beenconnected to the Plasma

Seite 6 - Sales and Support Information

14PLASMA DISPLAYINPUTSURROUNDVOLNRPICTURESOUNDSET UPASPECTPICTUREPOS. /SIZEOFF TIMERPCMULTIPIPSWAP SELECT MOVEINPUT MENU ENTER– +VOLOn-Screen Menu Dis

Seite 7 - Connections

152 Press toaccess eachadjust screen.Press the R button to return toprevious menu screen.Note: “Signal” setup menu displays different setting conditio

Seite 8 - PC Input Terminals connection

16ASPECT ControlsThe Plasma Display will allow you to enjoy viewing the picture at its maximum size, including wide screen cinemaformat picture.ASPECT

Seite 9 - SERIAL Terminals connection

17Adjusting Picture Pos./SizeAdjusting screen1Press to display the Picture Pos./Size menu.Press to adjust Pos./Size.Press to exit from adjust mode.Pre

Seite 10 - Basic Controls

18Picture Adjustments12Press to display the Picture menu.Select to adjust each item.Press to select the menu to adjust.Select the desired level by lo

Seite 11

19DetailsAdjusts the dark shades of the image in gradiation.(This cannot be adjusted when the input signal is RGB or DVI.)Adjustment of parts which ar

Seite 12 - AC cord connection

2Table of ContentsDear Panasonic CustomerWelcome to the Panasonic family of customers. We hope that you will have many years ofenjoyment from your new

Seite 13 - Select the input signal

20Sound Adjustment1Press to display the Sound menu.MutePress the R buttonUseful when answering the phone or receiving unexpected visitors.Press this b

Seite 14 - On-Screen Menu Displays

21Digital Zoom1324This displays an enlargement of the designated part ofthe displayed image.Display the "Operation Guide".Press to access Di

Seite 15

22PRESENT TIME Setup / Set up TIMERThe timer can switch the Plasma Display On or Off.Before attempting Timer Set, confirm the PRESENT TIME and adjust

Seite 16 - ASPECT Controls

23Set up TIMERPress to set upPOWER ON Time / POWER OFF Time. button: Forward button: BackPress to selectPOWER ON Time / POWER OFF Time.1Press to selec

Seite 17 - Helpful Hint ( /

24Screensaver (For preventing after-images)Do not display a still picture, especially in 4:3 mode, for any length of time.If any after-images are visi

Seite 18 - Normalise

25Screensaver (For preventing after-images )Setup of Screensaver TimePress to select Start Time/ Finish Time(When Time Designation is selected).Press

Seite 19

26Side Panel Adjustment2Press to select the Side panel.Press to select Off, Low, Mid, High.Press to exit from Screensaver.31Do not display a picture i

Seite 20 - Sound Adjustment

27Reducing power consumptionPress to select “On” or “Off”.Press to select“Power save”“Standby save”“Power management”“Auto power off”.• Power save: Wh

Seite 21 - Digital Zoom

28Setup for MULTI DISPLAY By lining up Plasma Displays in groups of 4 or 9 as illustrated below, an enlarged picture may be displayed acrossall screen

Seite 22 - PRESENT TIME

29Press to select Ratio (2nd step).Press to select “2×2”, “3×3”.How to set the display location number for each Plasma DisplayPress to select Location

Seite 23 - Set up TIMER

3Important Safety NoticeWARNING: 1) To prevent electric shock, do not remove cover. No user serviceable parts inside. Refer servicingto qualified serv

Seite 24 - Start setting

30Setup for Input SignalsComponent/RGB-in SelectSelect the input signals to be connected by installing the Optional Terminal Board.(Refer to the Opera

Seite 25 - Reducing screen after-image

31Setup for Input SignalsColour system / Panasonic AutoSelect Signal from the “Setup” menu during AV(S Video) input signal. (“Signal[AV]” menu is disp

Seite 26 - Side Panel Adjustment

32Select Signal from the “Setup” menu during RGB input signal.Press to adjust.Setting RGB sync signal:Confirm that the input is set to RGB input (this

Seite 27 - Reducing power consumption

33SymptomsChecksElectrical AppliancesCars/MotorcyclesFluorescent lightVolume(Check whether the mute function has beenactivated on the remote control.)

Seite 28 - Setup for MULTI DISPLAY

34signal namehorizontal verticalComponent RGBwhen Multi Screenfrequency (kHz) frequency (Hz) and Digital Zoom1 525 (480) / 60i 15.73 59.94∗∗ ∗2 525 (4

Seite 29 - C1 C2 C3

35Notes:(1) Design and specifications are subject to change without notice. Weight and dimensions shown are approximate.(2) This equipment complies wi

Seite 30 - Setup for Input Signals

Customer’s RecordThe model number and serial number of this product can be found on its back cover. You should note this serialnumber in the space pro

Seite 31

4Safety PrecautionsWARNINGSetupThis Plasma Display is for use only with the following optional accessories (subject to availability). Use withany othe

Seite 32 - Setting RGB sync signal:

5Safety PrecautionsIf problems occur during useIf a problem occurs (such as no picture or no sound), or if smoke or an abnormal odour starts to come o

Seite 33 - Troubleshooting

6PLASMA DISPLAYINPUTSURROUNDVOLNRPICTURESOUNDSET UPASPECTPICTUREPOS. /SIZEOFF TIMERPCMULTIPIPSWAP SELECTMOVESales and Support InformationStandard Acce

Seite 34 - Input signal can be displayed

7SERIALPC INAUDIO121212ConnectionsSPEAKERSTerminals (R)SPEAKERSTerminals (L)– Cable fixing bands Secure any excess cables with bands as required.W

Seite 35 - Specifications

8ConnectionsPC Input Terminals connectionNotes:(1) Computer signals which can be input are those with a horizontal scanning frequency of 15 to 110 kHz

Seite 36 - Customer’s Record

9SERIAL Terminals connectionNotes:(1) Use the RS-232C cable to connect the computer to the Plasma Display.(2) The computer shown is for example purpo

Kommentare zu diesen Handbüchern

Keine Kommentare