Panasonic CU-3KE19NBU Wartungshandbuch

Stöbern Sie online oder laden Sie Wartungshandbuch nach Split-System-Klimaanlagen Panasonic CU-3KE19NBU herunter. Panasonic CU-3KE19NBU Service Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 124
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
IMPORTANT
These air conditioners employ new
refrigerant R410A.
Pay special attention when
servicing the unit.
Wall mounted type
CS-MKE7NKU
CS-MKE9NKU
CS-MKE12NKU
CS-MKE18NKU
CS-MKE24NKU
< Applicable Indoor Units >
TECHNICAL & SERVICE MANUAL
OUTDOOR UNIT : CU-3KE19NBU
CU-4KE24NBU
CU-4KE31NBU
DC INVERTER MULTI-SYSTEM AIR CONDITIONER
Product Code No.
1 852 361 27
1 852 361 28
1 852 361 29
REFERENCE NO.
SM700878
Capacity at 230V
19,100 BTU/h
23,200 BTU/h
30,600 BTU/h
Outdoor Model No.
CU-3KE19NBU
CU-4KE24NBU
CU-4KE31NBU
CU-3KE19NBU
CU-4KE24NBU
CU-4KE31NBU
Semi-concealed type
CS-MKE9NB4U & CZ-18BT1U
CS-MKE12NB4U & CZ-18BT1U
CS-KE12NB4UW & CZ-18BT1U
Seitenansicht 0
1 2 3 4 5 6 ... 123 124

Inhaltsverzeichnis

Seite 1 - CU-4KE31NBU

IMPORTANTThese air conditioners employ newrefrigerant R410A.Pay special attention whenservicing the unit.Wall mounted typeCS-MKE7NKUCS-MKE9NKUCS-MKE12

Seite 2 - SAFETY PRECAUTIONS

Outdoor Unit CU-3KE19NBUIndoor Unit CS-MKE9NKU ×3Remarks:1. The values shown in performance section and electrical rating section above are based on

Seite 3 - Prohibit

41-2. Accessories Supplied with Unit Table 11-3. Optional Copper Tubing KitCopper tubing for connecting the outdoor unit to theindoor unit is availa

Seite 4 - Table of Contents

52. Installation Site Selection2-1. Indoor UnitAVOID: direct sunlight. nearby heat sources that may affect performance of theunit. areas where le

Seite 5

6 install the indoor unit more than 3.3' (1 m) away from anyantenna or power lines or connecting wires used for tele-vision, radio, telephone, s

Seite 6 - APPLICABLE INDOOR UNITS

7Fig. 4bUnion 1/2"(12.70mm)1/2"(12.70mm)Flare 3/8"(9.52mm)A joint for connecting tubes of different sizes (3/8"(9.52mm) 1/2&qu

Seite 7 - 1. OPERATING RANGE

8(B)Fig. 4dCBA(CS-MKE7NKU,CS-MKE9NKU,CS-MKE12NKU)(CS-MKE9NB4U,CS-MKE12NB4U)(CS-MKE7NKU,CS-MKE9NKU,CS-MKE12NKU)(CS-MKE9NB4U,CS-MKE12NB4U)DOutdoor unit

Seite 8 - 2. SPECIFICATIONS

9(A)Fig. 4gUnion 3/8"(9.52mm)Flare 1/2"(12.70mm)(1/2"(12.70mm) 3/8"(9.52mm)) Supplied ReducerDC(CS-MKE7NKU,CS-MKE9NKU,CS-MKE12

Seite 9

10(D)Fig. 4jUnion 5/8"(15.88mm)Flare 1/2"(12.70mm)(1/2"(12.70mm) 5/8"(15.88mm))Locally purchasedCD(CS-MKE7NKU,CS-MKE9NKU,CS-MK

Seite 10 - < 208V >

2-3. Outdoor UnitAVOID: heat sources, exhaust fans, etc. (Fig. 5a) damp, humid or uneven locations.DO: choose a place as cool as possible. choose

Seite 11 - < 230V >

12(1) Recommended dimensions of the baffle platesDFECJHLIBKQRAGO(3- 6.5 mm)3- 1/4"(2- 6 mm) 2- 15/64"ABHCEFKIJGGD(4- 6.5 mm)4

Seite 12 - Indoor Unit CS-MKE9NKU × 3

13(3) Installation procedurePanel topPanel frontPanel side RPanel side L1. Air Intake Baffle(1) Left side1. Remove the top panel from the unit.2. Remo

Seite 13

Outdoor Unit CU-4KE24NBUIndoor UnitDuct Less Type RatedCS-MKE7NKU × 2 + CS-MKE9NKURemarks:1. The values shown in performance section and electrical r

Seite 14 - Outdoor Unit CU-4KE31NBU

14Fig. 6a23-15/165-11/3215/3235-7/16 (900)13-19/3212-19/3214-17/322-29/3229-1/8 (740)23/321-13/162-1/165-29/322-27/322-3/42-1/324-7/162-15/162-3/44-1/

Seite 15 - Indoor Unit CS-MKE9NKU × 4

152-6. Diagram of Outdoor Unit InstallationNever install only a single indoor unit.Be sure to connect indoor and outdoor units only incombinations tha

Seite 16

163. Installation Process3-1. Embedding the Tubing and Wiring Do not connect tubes to locations that are embedded. Be sure to bind refrigerant tubi

Seite 17 - 2-2-1. Outdoor Unit

17When reaming, hold the tube end downward and be sure thatno copper scraps fall into the tube. (Fig. 9)(3) Remove the flare nut from the unit and be

Seite 18

183-6. Insulation of Refrigerant TubingTo prevent heat loss and wet floors due to dripping of con-densation, both tubes must be well insulated with a

Seite 19

194. Air PurgingAir and moisture remaining in the refrigerant system haveundesirable effects as indicated below. Therefore, theymust be purged comple

Seite 20

20Cap tightening torque:170 – 215 lbs·in(200 – 250 kgf·cm)(Tighten by hand, then use a wrench to turn approximately 45°.)StopperSpindleService

Seite 21 - 3. DIMENSIONAL DATA

21 Pump Down When relocating or disposing of the air conditioner, request thisservice from the dealer where the unit was purchased, or from anapprop

Seite 22 - (852-0-0010-20400-0)

225. Wiring Instructions5-1. General Precautions on Wiring(1) Before wiring, confirm the rated voltage of the unit asshown on its nameplate, then ca

Seite 23 - (852-0-0010-20300-0)

23WARNING Be sure to comply with local codes on running thewire from the indoor unit to the outdoor unit (sizeof wire and wiring method, etc.). Each

Seite 24 - 4. REFRIGERANT FLOW DIAGRAM

Outdoor Unit CU-4KE24NBUIndoor Unit CS-MKE9NKU × 3Remarks:1. The values shown in performance section and electrical rating section above are based on

Seite 25 - Indoor unit Outdoor unit

24When connecting each power wire to the correspondingterminal, follow the instructions “How to connect wiringto the terminal” and fasten the wire sec

Seite 26

25123123123123Indoor unit BIndoor unit AGroundPower:Single-phase,230/208VAC 60HZPower breaker(not provided)Outdoor unit Terminal boardLabel AInter-uni

Seite 27 - 5. PERFORMANCE DATA

26Regulations on wire size differ from locality to locality. Forfield wiring requirements, please refer to your local electri-cal codes. Make sure tha

Seite 28 - 75°F (24°C)

277. Connecting a Home Automation DeviceThe HA (white) 4P terminal is located on the indoor unit PCB. If a HA device will be used, connect it to this

Seite 30

Outdoor Unit CU-4KE24NBUIndoor Unit CS-MKE9NKU × 3Remarks:1. The values shown in performance section and electrical rating section above are based on

Seite 31

Outdoor Unit CU-4KE31NBUIndoor Unit CS-MKE7NKU × 3 + CS-MKE9NKURemarks:1. The values shown in performance section and electrical rating section above

Seite 32

Outdoor Unit CU-4KE31NBUIndoor Unit CS-MKE9NKU × 4Remarks:1. The values shown in performance section and electrical rating section above are based on

Seite 33

Outdoor Unit CU-4KE31NBUIndoor Unit CS-MKE9NKU × 4Remarks:1. The values shown in performance section and electrical rating section above are based on

Seite 34 - Indoor air temp. 73°F (23°C)

Outdoor Unit CU-3KE19NBU2-2-1. Outdoor UnitControl PCBControl Circuit Fuse ControlsPart No.Microprocessor250V 25ACB-CU-3KE19NBUDATA SUBJECT TO CHANGE

Seite 35

Outdoor Unit CU-4KE24NBUControl PCBControl Circuit Fuse ControlsPart No.Microprocessor250V 25ACB-CU-4KE24NBUDATA SUBJECT TO CHANGE WITHOUT NOTICE.Pint

Seite 36

Outdoor Unit CU-4KE31NBUControl PCBControl Circuit Fuse ControlsPart No.Microprocessor250V 25ACB-CU-4KE31NBUDATA SUBJECT TO CHANGE WITHOUT NOTICE.Pint

Seite 37

• Before doing repair work, please read the " SAFETY PRECAUTIONS" carefully and fully understand them. • The precautionary items here

Seite 38

Temperature F ( C)4035302520151050(-20)(-15)(-10) (-5) (0) (5) (10) (15) (20)-4 5 14 23 32 41 50 59 68Resistance (k ohm)032 50 68 86 104 122 140 158

Seite 39

Wide tube service valvedia.3/8" (9.52) ×3Narrow tube service valvedia.1/4" (6.35) ×34-7/165-29/32 2-27/32 2-3/42-1/32 4-1/22-15/162-3/429-

Seite 40

Wide tube service valvedia.1/2" (12.70) ×1Narrow tube service valvedia.1/4" (6.35) ×4Wide tube service valvedia.3/8" (9.52) ×34-7/16

Seite 41

Outdoor Unit CU-4KE31NBUUnit: inch(mm)(852-0-0010-20300-0) Wide tube service valvedia.1/2" (12.70) ×2Narrow tube service valvedia.1/4&qu

Seite 42

Compressor4-wayvalveHigh pressureswitchH.P.MainaccumulatorSubaccumulatorService valve onnarrow tubeService valve onwide tubeCNBNANCWBWAWO.D.1/4"O

Seite 43

4-wayvalveHigh pressureswitchH.P.Defrost valve forhot gas bypassOutdoor Unit CU-4KE24NBUInsulation of Refrigerant TubingBecause capillary tubing is u

Seite 44

CompressorMainaccumulatorSubaccumulatorService valve onnarrow tubeElectric expansion valveService valve onwide tube DNCNBNANDWCWBWAWO.D.1/4"O.D.1

Seite 45

Cooling Characteristics(RH : 46%, Indoor fan speed : High fan)(230V, 60Hz)Heating Characteristics(RH : 85%, Indoor fan speed : High fan)(230V, 60Hz)(1

Seite 46

Cooling Characteristics(RH : 46%, Indoor fan speed : High fan)(230V, 60Hz)Heating Characteristics(RH : 85%, Indoor fan speed : High fan)(230V, 60Hz)(1

Seite 47 - 70°F (21°C)

Outdoor Unit CU-3KE19NBU Indoor Unit CS-MKE12NKU ×1Cooling Characteristics(RH : 46%, Indoor fan speed : High fan)(230V, 60Hz)Heating Character

Seite 48 - 63°F (17°C)

WarningIf refrigerant gas blows off during the work, do not touch the refrigerant gas as it may cause frostbite.If refrigerant gas leaks during the wo

Seite 49

Cooling Characteristics(RH : 46%, Indoor fan speed : High fan)(230V, 60Hz)Heating Characteristics(RH : 85%, Indoor fan speed : High fan)(230V, 60Hz)(1

Seite 50 - 5-2. Cooling Capacity

• This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type.•

Seite 51 - < Cooling Capacity >

Outdoor Unit CU-3KE19NBU Indoor Unit CS-MKE12NB4U ×1• This performance chart shows operation of a single wall-mounted indoor unit. The perfor

Seite 52 - Outdoor Unit : CU-4KE24NBU

• This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type.•

Seite 53

Cooling Characteristics(RH : 46%, Indoor fan speed : High fan)(230V, 60Hz)Heating Characteristics(RH : 85%, Indoor fan speed : High fan)(230V, 60Hz)(1

Seite 54 - Outdoor Unit : CU-4KE31NBU

Cooling Characteristics(RH : 46%, Indoor fan speed : High fan)(230V, 60Hz)Heating Characteristics(RH : 85%, Indoor fan speed : High fan)(230V, 60Hz)(1

Seite 55

Outdoor Unit CU-4KE24NBU Indoor Unit CS-MKE12NKU ×1Cooling Characteristics(RH : 46%, Indoor fan speed : High fan)(230V, 60Hz)Heating Character

Seite 56

Cooling Characteristics(RH : 46%, Indoor fan speed : High fan)(230V, 60Hz)Heating Characteristics(RH : 85%, Indoor fan speed : High fan)(230V, 60Hz)(1

Seite 57

Cooling Characteristics(RH : 46%, Indoor fan speed : High fan)(230V, 60Hz)Heating Characteristics(RH : 85%, Indoor fan speed : High fan)(230V, 60Hz)(1

Seite 58

Cooling Characteristics(RH : 46%, Indoor fan speed : High fan)(230V, 60Hz)Heating Characteristics(RH : 85%, Indoor fan speed : High fan)(230V, 60Hz)(1

Seite 59

Table of Contents2467817202124275056626871778081828387...

Seite 60

Outdoor Unit CU-4KE24NBU Indoor Unit CS-MKE12NB4U ×1Cooling Characteristics(RH : 46%, Indoor fan speed : High fan)(230V, 60Hz)Heating Characte

Seite 61

Cooling Characteristics(RH : 46%, Indoor fan speed : High fan)(230V, 60Hz)Heating Characteristics(RH : 85%, Indoor fan speed : High fan)(230V, 60Hz)(1

Seite 62 - 5-4. Heating Capacity

Cooling Characteristics(RH : 46%, Indoor fan speed : High fan)(230V, 60Hz)Heating Characteristics(RH : 85%, Indoor fan speed : High fan)(230V, 60Hz)(1

Seite 63

Cooling Characteristics(RH : 46%, Indoor fan speed : High fan)(230V, 60Hz)Heating Characteristics(RH : 85%, Indoor fan speed : High fan)(230V, 60Hz)(1

Seite 64

Cooling Characteristics(RH : 46%, Indoor fan speed : High fan)(230V, 60Hz)Heating Characteristics(RH : 85%, Indoor fan speed : High fan)(230V, 60Hz)(1

Seite 65

146(1.0)174(1.2)118(0.8)90(0.6)Cooling Characteristics(RH : 46%, Indoor fan speed : High fan)(230V, 60Hz)Heating Characteristics(RH : 85%, Indoor fan

Seite 66

146(1.0)174(1.2)118(0.8)90(0.6)Cooling Characteristics(RH : 46%, Indoor fan speed : High fan)(230V, 60Hz)Heating Characteristics(RH : 85%, Indoor fan

Seite 67

Cooling Characteristics(RH : 46%, Indoor fan speed : High fan)(230V, 60Hz)Heating Characteristics(RH : 85%, Indoor fan speed : High fan)(230V, 60Hz)(1

Seite 68 - 6. ELECTRICAL DATA

Cooling Characteristics(RH : 46%, Indoor fan speed : High fan)(230V, 60Hz)Heating Characteristics(RH : 85%, Indoor fan speed : High fan)(230V, 60Hz)(1

Seite 69 - Outdoor Unit CU-4KE24NBU

146(1.0)174(1.2)118(0.8)90(0.6)Cooling Characteristics(RH : 46%, Indoor fan speed : High fan)(230V, 60Hz)Heating Characteristics(RH : 85%, Indoor fan

Seite 71 - 7. FUNCTIONS

Outdoor Unit : CU-3KE19NBUIndoor Unit : CS-MKE9NKU × 3Power Supply : 230V Single Phase 60Hz< Cooling Capacity >5-2. Cooling CapacityTC :

Seite 72 - Unit operation Explanation

Outdoor Unit : CU-3KE19NBUIndoor Unit : CS-MKE12NB4U × 3Power Supply : 230V Single Phase 60Hz< Cooling Capacity >TC : Total Cooling Capaci

Seite 73

Outdoor Unit : CU-4KE24NBUIndoor Unit : CS-MKE9NKU × 3Power Supply : 230V Single Phase 60Hz< Cooling Capacity >TC : Total Cooling Capacity

Seite 74 - (1/f fluctuation fan)

Outdoor Unit : CU-4KE24NBUIndoor Unit : CS-KE18NB4UW + CS-MKE12NB4U + CS-MKE12NB4UPower Supply : 230V Single Phase 60Hz< Cooling Capacity >

Seite 75 - 1/f fluctuation fan

Outdoor Unit : CU-4KE31NBUIndoor Unit : CS-MKE9NKU × 4Power Supply : 230V Single Phase 60Hz< Cooling Capacity >TC : Total Cooling Capacity

Seite 76 - 32 °F ( °C )

Outdoor Unit : CU-4KE31NBUIndoor Unit : CS-MKE9NB4U × 4Power Supply : 230V Single Phase 60Hz< Cooling Capacity >TC : Total Cooling Capacit

Seite 77 - 7-2. Protective Functions

Outdoor Unit : CU-3KE19NBUIndoor Unit : CS-MKE9NKU × 3Power Supply : 230V Single Phase 60Hz< Cooling Capacity (Low Ambient) >5-3. Cooling

Seite 78 - 7-2-2. Current Control

Outdoor Unit : CU-3KE19NBUIndoor Unit : CS-MKE12NB4U × 3Power Supply : 230V Single Phase 60Hz< Cooling Capacity (Low Ambient) >TC : Total

Seite 79 - 7-2-3. Low Start Current

Outdoor Unit : CU-4KE24NBUIndoor Unit : CS-MKE9NKU × 3Power Supply : 230V Single Phase 60Hz< Cooling Capacity (Low Ambient) >TC : Total Co

Seite 80

Outdoor Unit : CU-4KE24NBUIndoor Unit : CS-KE18NB4UW + CS-MKE12NB4U + CS-MKE12NB4UPower Supply : 230V Single Phase 60Hz< Cooling Capacity (Lo

Seite 81

APPLICABLE INDOOR UNITSCU-3KE19NBUCU-4KE24NBUCU-4KE31NBUMulti-Outdoor UnitIndoor Unit3-Room4-Room4-RoomCS-MKE7NKUYESYESYESYESYESYESYESYESYESNOYESY

Seite 82

Outdoor Unit : CU-4KE31NBUIndoor Unit : CS-MKE9NKU × 4Power Supply : 230V Single Phase 60Hz< Cooling Capacity (Low Ambient) >TC : Total Co

Seite 83

Outdoor Unit : CU-4KE31NBUIndoor Unit : CS-MKE9NB4U × 4Power Supply : 230V Single Phase 60Hz< Cooling Capacity (Low Ambient) >TC : Total C

Seite 84

Outdoor Unit : CU-3KE19NBUIndoor Unit : CS-MKE9NKU × 3Power Supply : 230V Single Phase 60Hz< Heating Capacity >5-4. Heating CapacityTH :

Seite 85

Outdoor Unit : CU-3KE19NBUIndoor Unit : CS-MKE12NB4U × 3Power Supply : 230V Single Phase 60Hz< Heating Capacity >TH : Total Heating Capaci

Seite 86

Outdoor Unit : CU-4KE24NBUIndoor Unit : CS-MKE9NKU × 3Power Supply : 230V Single Phase 60Hz< Heating Capacity >TH : Total Heating Capacity

Seite 87

Outdoor Unit : CU-4KE24NBUIndoor Unit : CS-KE18NB4UW + CS-MKE12NB4U + CS-MKE12NB4UPower Supply : 230V Single Phase 60Hz< Heating Capacity >

Seite 88 - 9. REFRIGERANT R410A:

Outdoor Unit : CU-4KE31NBUIndoor Unit : CS-MKE9NKU × 4Power Supply : 230V Single Phase 60Hz< Heating Capacity >TH : Total Heating Capacity

Seite 89

Outdoor Unit : CU-4KE31NBUIndoor Unit : CS-MKE9NB4U × 4Power Supply : 230V Single Phase 60HzTH : Total Heating Capacity (BTU/h)1.Rating conditio

Seite 90

6. ELECTRICAL DATA6-1. Electric Wiring DiagramsOutdoor Unit CU-3KE19NBU8FA2-5251-11700-168

Seite 91

Outdoor Unit CU-4KE24NBU8FA2-5251-11500-169

Seite 92

95 °F DB / 71 °F WB67 °F DB / 57 °F WB80 °F DB / 67 °F WB– DB / – WB1. OPERATING RANGEMaximumMinimumMaximumMinimum115 °F DB14 °F DB75 °F DB / 65 °F W

Seite 93

Outdoor Unit CU-4KE31NBU8FA2-5251-11300-170

Seite 94 - 9-8-1. Use of Existing Units

7. FUNCTIONS7-1. Explanation of FunctionsThe numerical values such as temperature, frequency, time and current in parentheses are an example of CU-4

Seite 95

Control/conditionsHEATWhen defrost operation begins, frost has formed on the outdoor unit (when the ambient air temperature is low).Defrost operation

Seite 96 - APPENDIX A

Control/conditionsCOOLThe ON/OFF operation button on the remote controller is pressed.The room temperature has reached the desired temperature.The out

Seite 97 - Split System Air Conditioner

Control/conditionsSENSOR DRY(1/f fluctuation fan)The ON/OFF operation button on the remote controller is pressed.The outdoor unit does not operate for

Seite 98 - Please Read Before Starting

1/f fluctuation fan2502006-minute cycleFig. 2150100(Step)50075

Seite 99 - When Servicing

< Low Ambient Cooling Operation >When the mode is switched from cooling opration to low ambient cooling operation,the compressor is stopped for

Seite 100 - 1. General

7-2. Protective Functions7-2-1. Defrost Detection and Release(2) Clean defrostIf all indoor units are stopped during HEAT operation, and frost is de

Seite 101

7-2-2. Current ControlThe operating current may rise as a result of causes including increasing heating or cooling loads or decreases in power voltag

Seite 102

7-2-5. Control at HEAT Start-upIf HEAT operation is started when the outdoor air temperature is 59 °F or below, the unit operates at the HEAT start-u

Seite 103

2. SPECIFICATIONS2-1. Unit SpecificationsOutdoor Unit CU-3KE19NBUIndoor Unit CS-MKE9NKU × 2Remarks:1. The values shown in performance section and e

Seite 104

8. TROUBLESHOOTING (BEFORE CALLING FOR SERVICE)8-1. Precautions before Performing Inspection or RepairBoth the indoor unit and outdoor unit include

Seite 105

8-2. Trouble Diagnosis by Error Monitor Lamps8-2-1. Location of the Error Monitor LampsRemove the top plate of outdoor unit and the cover of Electri

Seite 106

8-3-1. Checking the outdoor unit8-3. Checking the Outdoor System8-3-2. Checking the defrost operationWork procedureApply 220 V AC between terminals

Seite 107 - About 16" (40 cm)

8-4. Trouble Diagnosis of Each Part8-4-1. Problems of Each Part and Inspection PointsFor details about the inspection points, refer to the Inspectio

Seite 108 - Air Intake Baffle

ProblemsInspectionpointsIndoor unitIndoor unit does not operate.BreakerRefrigerant gas pressure(9)(10)Operation lamp blinking.Operation lamp does not

Seite 109

No voltage on circuit board(7) Electric expansion valveWhen replacing the electric expansion valve and coil, be sure to attach the connectors in the c

Seite 110

(8) Branch tubing temperature sensorCheck that the sensor is securely contained in the thermostat holder.(9) BreakerCheck whether or not the breaker h

Seite 111 - Access panel C

8-5. Trouble Diagnosis of Fan MotorThis outdoor DC fan motor contains an internal control PCB. Therefore, it is not possible to measure the coil resi

Seite 112 - 3. Installation Process

9. REFRIGERANT R410A: SPECIAL PRECAUTIONS WHEN SERVICING UNIT9-1. Characteristics of New Refrigerant R410A9-1-1. What is New Refrigerant R410A?R410

Seite 113 - Service valve on

Tubing precautionsRefrigerant R410A is more easily affected by dust or moisture compared with R22, thus be sure to temporarily cover the ends of the t

Seite 114

Outdoor Unit CU-3KE19NBUIndoor Unit CS-MKE9NKU × 3Remarks:1. The values shown in performance section and electrical rating section above are based on

Seite 115 - (for Test Run)

9-3. Tools Specifically for R410A For servicing, use the following tools for R410AGauge manifoldCharging hoseGas leak detectorRefrigerant cylinderCha

Seite 116

9-5. In Case of Compressor Malfunction CAUTIONShould the compressor malfunction, be sure to make the switch to a replacement compressor as quickly as

Seite 117 - Pump Down

ValveSingle valveCharge liquid refrigerant with cylinder in up-side-down position.Single valve (with siphon tube)Charge with cylinder in normal positi

Seite 118 - 5. Wiring Instructions

Length of tubingEvacuation timeLess than 33 ft. (10 m)More than 10 minutesMore than 33 ft. (10 m)More than 15 minutes9-6. In Case Refrigerant is Lea

Seite 119

9-7. Charging Additional Refrigerant9-7-1. When Tubes are ExtendedObserve the proper amount of refrigerant as stated in this service manual or the i

Seite 121

INSTALLATION INSTRUCTIONSCU-3KE19NBUCU-4KE24NBUCU-4KE31NBU(852-6-4190-584-00-2)APPENDIX AA-1

Seite 122 - 6. Test Run

For Outdoor UnitThis air conditioner uses the refrigerant R410A. External diameter of service port R410A: 5/16" Split System Air Conditioner 8526

Seite 123 - 8. Installation Check Sheet

IMPORTANT! Please Read Before StartingThis air conditioning system meets strict safety and operatingstandards. As the installer or service person, it

Seite 124 - DC1111-0

 8VHWKHIODUHPHWKRGIRUFRQQHFWLQJWXELQJ $SSO\UHIULJHUDQWOXEULFDQWWRWKHPDWFKLQJVXUIDFHVRIthe flare and union tubes before connecting them