Panasonic WJSX550_SERIES Betriebsanleitung

Stöbern Sie online oder laden Sie Betriebsanleitung nach Sicherheitskameras Panasonic WJSX550_SERIES herunter. Panasonic WJSX550_SERIES Operating Instructions Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 138
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Before attempting to connect or operate this product, please read these instructions completely
Matrix Switcher
WJ-SX550A
System Controller
WV-CU550A
ENGLISH
DEUTSCH
FRANÇAIS
Seitenansicht 0
1 2 3 4 5 6 ... 137 138

Inhaltsverzeichnis

Seite 1 - WV-CU550A

Before attempting to connect or operate this product, please read these instructions completelyMatrix SwitcherWJ-SX550ASystem ControllerWV-CU550AENGLI

Seite 2 - DO NOT OPEN

In Matrix Switchers the activation (or closure) of a crosspoint switch is performed by a microprocessor. This microprocessor mayget its commands from

Seite 3

-96-If an Operator No. or Password error has occurred, a‘No entry’ display appears on the LCD and the displayautomatically returns to the Log-in displ

Seite 4 - PRECAUTIONS

-97-2. Operation MenusAfter log-in, the following operation menus are available on the LCD by pressing the appropriate Cursor Keys. For example, to go

Seite 5 - HOW TO USE THIS MANUAL

-98-4. Camera SelectionSelect the desired camera by pressing the Numeric Keys,then press the Camera (CAM) Key.3. Monitor SelectionSelect the desired m

Seite 6 - TABLE OF CONTENTS

-99-6. Controlling System AccessoriesControls for system accessories are located on the rightside of the front panel of the System Controller.Included

Seite 7

-100-6-3 Pan/Tilt Control (Preset Operation)The following function is only available with cameras thathave preset panning functions, such as the Panas

Seite 8 - A MATRIX

-101-6-5 Pan/Tilt Control (Auto/Random Panning)The functions described below are available only when thespecified Pan/Tilt Head is used.MODEL AUTO-PAN

Seite 9 - ■ Spot and Sequence

-102-7. Running a Sequence7-1 Program SequenceThe following functions are available only if a ProgramSequence has been previously established for a pa

Seite 10 - Matrix Switcher

SEQALTFORWARD-103-8. Press the Decrement (DEC - 1CAM) Switch to move asequence one step backward from the step that waspreviously stopped by the Stop

Seite 11

-104-6. Press the Backward Sequence (BACK SEQ) Switch tocontinue a sequence that was previously stopped bythe Stop (STOP) Switch. The sequence will co

Seite 12 - Monitor 2

-105-5. Press the Stop (STOP) Switch to stop the GroupSequence.G-Seq 01 Stop Monitor 16STOP6. Press the Forward Sequence (FORWARD SEQ)Switch

Seite 13

SignalSynchronizingSignal (VD2)Unique VD2 signal is sent to Panasonic cameras to synchronize the cameras with theMatrix Switcher, thereby preventing r

Seite 14 - SWITCHER

-106-9. Title Display1. Select the desired camera and monitor.Refer to the Camera and Monitor Selection on page98.Camera 01 Monitor 162. Pres

Seite 15 - TL TL TL TL

-107-10. Camera Operation10-1 Electronic Shutter ModeThe following function is available only when specifiedcameras with the electronic shutter featur

Seite 16 - 1. Log-in

-108-Press the Function (F3) Key to select a lower sensitivi-ty up setting or press the Function (F4) Key to select ahigher sensitivity up setting.F3:

Seite 17 - 3. Camera Control

-109-4. Press the Function (F3 or F4) Key repeatedly to selectthe desired zooming area. The emphasized area isswitched over on the monitor as shown in

Seite 18 - Program Sequence

-110-10-6 Camera Set UpThe following functions are only available with camerasthat have set up functions such as the Panasonic WV-CP610 or WV-BP510 se

Seite 19 - Tour Sequence

-111-3. Press the Function (F4) Key repeatedly to display orerase the camera status as shown below.Site StatusEle Zoom:Shutter :Sens Up :Random :Auto

Seite 20 - Group Sequence

-112-3. Press the Function (F1) Key to select the PresetProgram Mode.The Preset Program Menu appears on the selectedmonitor.Refer to the Preset Progra

Seite 21 - 8-3. Alarm Recall

-113-3. Set the desired preset position by moving the JoystickController, and adjust the zoom and focus by pressingthe Zoom (ZOOM TELE/WIDE) Control a

Seite 22 - 10. Camera Title

Preset/BLC Clear Pre BLCF1 F2 F3 F4-114-61. Move the cursor to the HOME POSITION by movingthe Joystick Controller, and enter the desired positionnumb

Seite 23 - 11. Status Display

-115-15. Camera Position Number SettingThe following function is available only when the ModeSelection Switch is selected at CAM-P Mode on the rear of

Seite 24 - 15. RS-485 Site Communication

-9-• Examples of Advanced ApplicationsAs previously described, the Matrix Switcher controls both the crosspoint switches and external devices. By com

Seite 25 - Pr64 T32 Room 306

-116-15-3 Camera Position Test Mode1. Select the desired monitor.Refer to the Monitor Selection on page 98.2. Select the CAM-P (D5) Menu as shown belo

Seite 26 - SELECTION

-117-16. Priority LockThis function is used to retain control of a monitor by anoperator, even after that operator has selected anothermonitor or has

Seite 28 - CPU Board

-119-TROUBLESHOOTING7

Seite 29 - VD output signal

-120-TROUBLESHOOTINGA majority of the problems encountered in operating a matrix switcher can be traced to incorrect hardware or software setup.Theref

Seite 30

-121-Symptom: While running the Preset Test, the WV-CS500 Combination Camera stops at preset positions for extendedperiods of time.1. If the WV-CS500

Seite 31 - Control Board

-122-7Symptom: The Alarm does not work.1. Check that the Alarm Mode is selected “ Mode 1 - 3 “ or Timer on the Alarm Mode Select Menu in the Set Up Me

Seite 32

-123-SPECIFICATIONS8

Seite 33 - WV-PB5508E Video Input Board

-124-SPECIFICATIONS WJ-SX550A Matrix SwitcherGeneralPower Supply: 220-240V AC 50 HzPower Consumption: Approx. 20W (Max. 75W with all optional boards

Seite 34

-125- WV-PB5504AE Video Output BoardMonitor Output (1 - 4): 1.0V[p-p]/75Ω composite video signalMonitor Input (1 - 4): 1.0V[p-p]/75Ω composite video

Seite 35 - RECOVER IN

-10-Alarm 3 input by infrared sensorhMonitor 1Monitor 2Step(1) Camera 1 picture is shown for 1 second(2) Camera 4 picture at preset 1 position is show

Seite 36

-126- WV-PB5548E Data BoardData Input/Output(1 - 8): RS-485 (Full Duplex or Half Duplex, selectable inside the switch)[5-pin T(A), T(B), R(A), R(B),

Seite 37

-127-9INDEX

Seite 38 - WV-CU550A System Controller

-128-AAlarm Acknowledge and Reset Switch ... 36, 111Alarm Board ... 12, 32, 40, 42, 47, 60Alarm Ind

Seite 39

-129-FFocus Control ... 35, 98, 99, 113Forward Sequence ...

Seite 40

-130-SSens Up Menu ... 107Sequence ... 6, 15, 7

Seite 42 - Extension Board

-132-DEUTSCHE AUSGABE(GERMAN VERSION)Die in dieser Bedienungsanleitung aufgeführten Modellnummern weisen keinen Anhang auf.Das Blitzzeichen mit Pfeil

Seite 44 - WV-PB5564E Alarm Board

N0396-0156 YWV8QA4204BN Printed in JapanN 19 Gedruckt in JapanImprimé au JaponMatsushita Electric Industrial Co., Ltd.Central P.O. Box 288, Osaka 530-

Seite 45

-11-FEATURESOF THESYSTEM 500MATRIXSWITCHER2

Seite 46

-12-FEATURES OF THE SYSTEM 500 MATRIX SWITCHERPrefaceThe system shown below is an example of the expansion capabilities of the WJ-SX550A Matrix Switch

Seite 47 - WV-PB5548E Data Board

-13-1. Log-inTo operate the Matrix Switcher System 500, a registeredoperator must first supply their Operator Number andPassword to the system control

Seite 48

-14-Note: The desired monitor selection may not be avail-able due to one of the following reasons:1. The System Controller used for selecting a partic

Seite 49 - Extension

-15-5. Preset ControlThe preset function is used to memorize the setting points of focus, zoom, pan and tilt of a desired scene in advance, and to bea

Seite 50

-16-• Auto Skip FunctionThe Auto Skip function is available in sequence. If there is no video signal present at a step, the sequence will automaticall

Seite 51

The serial number of this product may be found on thebottom of the unit.You should note the serial number of this unit in thespace provided and retain

Seite 52

-17-6-3. Group SequenceA Group Sequence consists of up to 64 steps.In each step a maximum of 16 cameras can be assigned to 16 monitors.Pan/Tilt preset

Seite 53 - CONNECTIONS

-18-The following are the examples of these modes.Alarm Mode 1: Any alarms to 1 monitorMode 1 displays all alarms on Monitor One. If more than one ala

Seite 54

-19-9. Operator RegistrationIn the Operator Registration, an operator's level, priority, password and camera access limits are determined. Up to

Seite 55

-20-11. Status Display12. System Controller-Monitor PartitioningThis feature is used to prevent specific WV-CU550A System Controllers from controlling

Seite 56 - Installing Boards

-21-Setting Procedure1. Operator No.1 has first priority . Cameras 1 - 8 can be selected by MON-1.2. Operator No.2 has second priority. Cameras 1-5 ca

Seite 57 - SYSTEM CONNECTIONS

-22-16. Communication SpeedThe data transmitting/receiving rate can be set by using the Set Up Menu.Usually, the Baud Rate is set to 9,600 bps, with a

Seite 58 - VIDEO OUT2

-23-DETAILEDPRODUCTDESCRIPTIONANDSELECTION3

Seite 59 - Connection with the Monitors

-24-MAJOR OPERATING CONTROLS AND THEIR FUNCTIONSWJ-SX550A Matrix Switcher1. Operation Indicator (OPERATE)This indicator lights up when the WJ-SX550A M

Seite 60

Pin No.Pin No.-25-CPU Board1. RS-232C Port (RS-232C)This port is used to connect a personal computer that can store or load the memory in the WJ-SX550

Seite 61

This board should be installed in the WJ-SX550A Matrix Switcher even if the WJ-AD550Extension Unit is used.-26-4. VS/VD Input Connector (VS/VD IN)Eith

Seite 63

-27- CPU Board Dip Switch and Jumper Setting2. Set the switch (SW4) on the board to match the Sync. input signal, if applicable. Initially, VSpositi

Seite 64

Pin No.-28-Control Board1. Data Port (DATA 1 - 8)These ports are used to transmit/receive control data to/from the WV-CU550A SystemController. Eight

Seite 65 - Camera Site

-29- Control Board Dip Switch SettingConfirm switches (SW2) on the board are set to the following positions.These switches are used only for factory

Seite 66 - 300, 350, 400, 450

Pin No.-30-WV-PB5508E Video Input Board1. Video Output Connector (VIDEO OUT 1, 2)The video signal connected to the Camera Input Connector (CAMERA IN)

Seite 67 - (“Daisy-Chain” Type Wiring)

-31- WV-PB5508E Video Input Board Dip Switch SettingSet switches (SW1) on the board to meet the camera input number as shown in the following table.I

Seite 68

-32-3OUT INOUT INOUT INOUT INMONITORALARM OUTRESET OUTEXT TIMING INRECOVER INOUTPUT1234 WV-PB5504AE Video Output Board1. Alarm Output/Reset

Seite 69 - SOFTWARE

P/ E/A/B/GEIAstandard CCIR standardSPECIFICATIONSScanning: 525 lines / 60 fields / 30 frames 625 lines / 50 fields / 25 framesHorizontal: 15.734 KHz

Seite 70

-33- WV-PB5504AE Video Output Board Dip Switch Setting1. Set switches (SW1) on the board to meet the monitor output number as shown in the following

Seite 71 - ■ Set Up Programming Menu

-34-1 2 34 5 67 8 9MON CAMESC SET0ACKRESETBACKSEQFORWARDSEQ ALTDEC-1CAMINC+1CAMSTOP12AUXCLOSEOPENIRISPRESETFOCUSNEARZOOMTELEFARWIDESystem Controller W

Seite 72 - 1. Set Up Menu

-35-1. Alarm Indicator (ALARM)This LED indicator blinks to indicate an alarm condi-tion exists.2. Busy Indicator (BUSY)This LED indicator lights up

Seite 73 - 3. Program Sequence (P-SEQ)

-1-PREFACEThe WJ-SX550A Matrix Switcher, when combined with theoptional WV-CU550A System Controller and WJ-AD550Extension Unit, allows for flexible co

Seite 74 - 4. Tour Sequence (T-SEQ)

-36-17. Auxiliary Switches (AUX 1,2)These switches are used to control the auxiliaryswitches inside the Receiver (WV-RC100, WV-RC150or WV-RC170 ).For

Seite 75 - 5. Group Sequence (G-SEQ)

-37-1. Operation Indicator (OPERATE)This indicator lights up when the WJ-AD550 ExtensionUnit is turned power on.2. Extension Board (EXTENSION)One of t

Seite 76 - 7. Event Menu

-38-Extension Board1. EXtension Connector ( 1, 2 )These connectors are used to expand the Matrix Switcher System. Connect each connectorbetween the bo

Seite 77 - 8. Timer Event Schedule

-39- Extension Board Switch SettingSW1AD550SX550ASW3AD550SX550A1. Set switches (SW1/SW3) on the board to choose thesystem requirement as shown below.

Seite 78 - 9. Special Day Schedule

ALARMTEST1-325RESETMODE33-64-40-WV-PB5564E Alarm Board32. Mode Selection Switch (MODE)This rotary switch, in combination with the test switch, is used

Seite 79 - 10. Alarm Menu

12345678910111213141516171819Alarm 1Alarm 2Alarm 3Alarm 4Alarm 5Alarm 6Alarm 7Alarm 8Alarm 9Alarm 10Alarm 11Alarm 12Alarm 13Alarm 14Alarm 15Alarm 16Al

Seite 80 - 11. Alarm Mode Select

65-7273-8081-8889-9697-104105-112113-120121-128-42-3. Confirm switchers (SW12) on the board are set to the following positions.12OFFSW12These switches

Seite 81 - 12. Set Up Alarm Mode 1

-43-WV-PB5548E Data Board1. Data Connector (TA/TB/RA/RB/GND, 1 - 8)These connectors are used to transmit/receive control data to/from the camera site

Seite 82 - 13. Set Up Alarm Mode 2

-44- WV-PB5548E Data Board Dip Switch Setting1234OFFSW11234OFFSW3SW100SW150SW200SW250SW300SW350SW400SW450SW5SW6BOARDNO.1234OFF1234OFF1234OFF1234OFF12

Seite 83 - 14. Set Up Alarm Mode 3

-45-BOARD SELECTION FOR SYSTEM EXPANSIONThis switcher has 15 slots, clever of which are available for system expansion.The CPU and Control Board, alon

Seite 84 - 5. Error (E) display

-2-HOW TO USE THIS MANUALThe purpose of this manual is to provide step-by-step instructions for setting up and operating a Matrix System 500. If Matri

Seite 85 - 15. Timer Alarm Schedule

CamerasCameras-46-1 - 89 - 1617 - 2425 - 3233 - 4041 - 4849 - 5657 - 641 - 41 - 41 - 41 - 41 - 41 - 41 - 41 - 4not requirednot requirednot requirednot

Seite 86 - 16. Operator Menu

-47-Cameras1 - 89 - 1617 - 2425 - 3233 - 4041 - 4849 - 5657 - 649 - 129 - 129 - 129 - 129 - 129 - 129 - 129 - 12not requirednot requirednot requiredno

Seite 88 - 19. Camera Title

-49-INSTALLATIONANDSYSTEMCONNECTIONS4

Seite 89 - 21. Status

-50-4INSTALLATIONThe installation described below should be made by quali-fied service personnel or system installers. WV-CU550A System ControllerRep

Seite 90 - 23. Controller

-51-1. Remove the screws from the rear panel(s) of theMatrix Switcher.2. Remove the rear panel(s).3. Place the Board into the desired position in the

Seite 91 - 24. EXT Timing Select

-52-• Extension Unit is requiredWhen the Extension Unit is required to install the boards, itis recommended to install the boards as shown below.Remov

Seite 92 - 01 02 03

-53-SYSTEM CONNECTIONSOver View of System ConnectionTL TLTL TLCPURS-232CTIMEADJUST INCOMPRINTEROUT INVS/VDVDOUTOFF+9V+5V−5VPOWERON11A00001OUT IN1O

Seite 93 - 26. RS-485 Site Communication

-54- Connection with the Camera SitesConnect the Camera Site Equipments to the CameraInput Connectors (CAMERA IN, 1-8) on the VideoInput Board.Cautio

Seite 94 - 27. Communication Speed

-55- Connection with the MonitorsConnect the Monitors to the Monitor Output Connec-tors (MONITOR OUT) on the Video Output Board(s).TLTLTLTL2 4 6 8 10

Seite 95 - 28. Clock Set

§1 BASIC OPERATION OF A MATRIX SWITCHER PAGE 5 - 10§2 FEATURE OF THE SYSTEM 500 MATRIX SWITCHER PAGE 11 - 22§3 DETAILED PRODUCT DESCRIPTION AND SELECT

Seite 96

-56- Connection with the System Controllers• Data Line and Unit Number SettingUp to eight WV-CU550A System Controllers may beinstalled in a Matrix S

Seite 97 - PROCEDURES

-57-IN OUTTERMON OFFDATA0123456789CONTROLLERUNIT NO.1-8Controller 1IN OUTTERMON OFFDATA0123456789CONTROLLERUNIT NO.1-8Controller 2IN OUTTERMON OFFDATA

Seite 98 - Power Up Display

-58-• Indirect connection between the Control Board and System Controllers (“Daisy-Chain” Type Wiring)In this type of installation only one control ca

Seite 99 - OPERATING PROCEDURE

Combination Connections-59-• Combination of direct and indirect connections between the Control Board and System Controllers (Both“Home Run” and “Dais

Seite 100 - ‘Monitor Busy‘

-60- Connection with the Alarm Sensor UnitsConnect the sensor switches to the Alarm InputConnector on the Alarm Board as shown in the exam-ple below.

Seite 101 - 2. Operation Menus

-61-4 Connection between the Data Board andCamera SiteConnect the Data Board and the Camera Controller byspecified data cable.Basically, connect sho

Seite 102 - 3. Monitor Selection

-62-ModelsParameters2 Line (Half Duplex) ConnectionSet the same Communication Parameters on the Setup Menus of the Matrix Switcher and Camera Controll

Seite 103 - 6-1 Lens Control

-63-• Indirect Connection between the Data Board and Camera Controllers(“Daisy-Chain” Type Wiring)In this type of connection only one control cable di

Seite 104 - Monitor 16

-64-It is only available an alarm data connected unit in aDaisy-Chain. Set the Mode Selection Switch on the oneof Camera Controllers to the “NORMAL” p

Seite 105 - F1 F2 F3 F4

-65-SOFTWARESETUP5

Seite 107 - 7-2 Tour Sequence

-66-SET UP MENUThe Set Up Menu provides a way for controlling functionsnot available through direct keyboard input. It is accessi-ble to system operat

Seite 108

-67-Set UpProgram Program Sequence ... Page 69Tour Sequence ...

Seite 109 - 8. Displaying Playback Video

-68-To Select an Item from the Set Up Menu:1. Move the cursor to the desired item by moving the Joystick Controller.2. Press the Set (SET) Key to exec

Seite 110 - Pr64 Sp Room 306

-69-3. Program Sequence (P-SEQ)After selecting the Program Sequence sub menu, a table appears on the monitor.This table is used to programme or edit a

Seite 111 - 10. Camera Operation

-70-4. Tour Sequence (T-SEQ)This table is used to programme or edit a Tour Sequence.There are 32 Tour Sequences available, each with 64 steps.Each ste

Seite 112 - Camera 01

-71-5. Group Sequence (G-SEQ)This table is used to programme or edit a Group Sequence. A Group Sequence consists of up to 64 steps. Each step can assi

Seite 113

-72-6. Timer MenuAs shown below, the Timer Menu allows access to two items, Event and Special Day Schedule. With these two items it is possibleto enab

Seite 114

-73-8. Timer Event ScheduleThis table is used to enable and disable Tour and Group Sequences according to the time of day and day of the week.There ar

Seite 115

-74-9. Special Day ScheduleBefore programming this table, confirm that the Timer Event Schedule (Special Day 1-5) is programmed completely.This table

Seite 116 - Room 306

-75-10. Alarm MenuAs shown below, the Alarm Menu allows access to five items: Alarm Mode Select, Set Up Alarm Modes 1-3 and Timer AlarmSchedule..Set U

Seite 117 - 14-2 Preset Program Menu

-5-BASICOPERATIONOFA MATRIXSWITCHER1

Seite 118

-76-11. Alarm Mode SelectThere are 5 Alarm modes available, Mode-1, Mode-2, Mode-3, Off mode and Timer mode.In Alarm mode-1, All alarm inputs are dis

Seite 119

-77-12. Set Up Alarm Mode 1This table can be set up only after the alarm mode is set to the Off mode in the Alarm Mode Select table.1. Move the cursor

Seite 120 - ■Act Exit

-78-1. Move the cursor to the 4 position by moving the Joystick Controller, then press the Set (SET) Key.2. Move the cursor to the 5 position by movin

Seite 121

-79-14. Set Up Alarm Mode 3This table can be set up only after the alarm mode is set to the Off mode in the Alarm Mode Select table.There is a total o

Seite 122

-80-5The follows are explanation on the setup example 1 to 6 in the table.1. Spot (S) Setup example 1When an Alarm is activated, it is able to display

Seite 123 - TROUBLESHOOTING

-81-15. Timer Alarm ScheduleThis table can be set up only after the alarm mode is set up to the Off mode in the Alarm Mode Select table.This table is

Seite 124

-82-UpLevelOperatorF1:-- F2:-- F3:-- F4:--Set OPE.RegistrationTableTo select an item from the Operator Menu:1. Select the desired item by moving the J

Seite 125

-83-18. Operator RegistrationThis table is used to establish operator numbers for the users of the system, along with associated passwords, operator l

Seite 126

5-84-19. Camera TitleThere are 128 camera titles available.Each title is composed of 15 characters per line, times 2 lines.1. Move the cursor to the 2

Seite 127 - SPECIFICATIONS

-85-20. Alarm RecallThere are 99 alarm records stored in chronological order in 7 pages of tables.The tables also show all involved monitor numbers wh

Seite 128

-6-BASIC OPERATION OF A MATRIX SWITCHER Crosspoint SwitchesSW11 SW21 SW31 SW41SW12 SW22 SW32 SW42SW13 SW23 SW33 SW43SW14 SW24 SW34 SW44SW15 SW25 SW35

Seite 129 - ■ WV-CU550A System Controller

5-86-22. System MenuAs shown below, the system menu allows access to six items.UpControllerEXTCompensation/VD2CommunicationClockF1:-- F2:-- F3:-- F4:-

Seite 130 - ■ WV-Q63E Blank Panel

-87-24. EXT Timing SelectThis table permits the sequence dwell time on the selected monitor to be synchronized with the time lapse mode set in the ass

Seite 131

-88-25. Compensation/VD2This table is used to for selecting the most suitable position of the cable-loss compensator and to turn on or off the VD2 (Sy

Seite 132

-89-26. RS-485 Site CommunicationThis table is used to set the Communication Parameters between the Data Boards installed in the Matrix Switcher and t

Seite 133

-90-27. Communication SpeedThis table is used to set the Communication Parameters between the System Controllers (or PCs) and the Matrix Switcher.1. M

Seite 134

-91-28. Clock SetThis table is used to set the present time and date.Note: The date and time are updated when the Escape (ESC) Key is pressed.1. Move

Seite 136 - DEUTSCHE AUSGABE

-93-OPERATINGPROCEDURES6

Seite 137

-94-Power Up DisplayWhen the power switch of the Matrix Switcher is turned on, a screen similar to the one shown below is displayed on the all moni-to

Seite 138 - Imprimé au Japon

-95-OPERATING PROCEDUREBefore starting the following procedures, all system com-ponents should be turned on.1. Log-in1. Turn on the power switches of