PanasonicNetwork Interface UnitOperating InstructionsWJ-NT204 WV-CU20Model No.Before attempting to connect or operate this product, please read these
Access from an InternetThe PC accesses to the Remote site via Internet,Remote SiteControl Site 110
WJ-FS616 CAMERA MENU SETUP PAGEi] ...|**W|e] win«: 1«...; iioCESEnffl^Sji^ETWORKjj:i [VIDEO £EO AlAitM,£ERLALPCRT’’’VSRR: ioorT; pATE/TIME CA
PS-Data MENU SETUP PAGE:U (EQ01^*»*1*1 hirt ' - — - 'i."I."...“—^ ...i WOMiTETU?Mli ITETWOUKi V
PS-Data CAMERA MENU SETUP PAGEAB&amnrRAtoitliEniF iP4GK:r-ACiK:iRECHVlKGs':«f3№4^93CC!ii¥«!4l:d* '' "xPS.Dota CAMERA MENU SETU
MLITYiSOMARE• Confirmation of the set valuesTurn OFF all Mode Setup switches inside the WJ-NT204 front panel, and then press the RESET
Ä8CESS AUTHORIZATION Control of Access AuthorizationUser access authorization is controlled as follows.• Unlimited accessIf neither user nor host au
RegistrationAdministrator level (Level 1) users only can be registered in the HOST SETUP and USER SETUP windows.Each window is provided with fields
EXTENSION FUNCTIONSYou may see dark stripes in the edges of image display. These are added by the'devices connected to the transmitter for the ad
® WJ-NT204 DIRECT COAXIAL CAMERA SELECTSelect the input number to the WJ-NT204 from 1 to 4 and AUX,WJ-MP204 CAMERA SELECTWhen AUX is selected,
WJ-FS616 Video Multiplexer Control• Connection(1) Connect MULTISCREEN OUT on the rear of the WJ-FS616 to VIDEO IN 1 on the rear of the WJ-NT204.(2
® VCR CONTROL PANELOpens the VCR control panel on the bottom center oi the window.(D VCR/CAMERA SELECTAlters the FS616's output between the
Front View© Power Switch & Power Indicator [POWER]Press this switch to turn on or olí the power of the unit. The indicator lights while the power
• WJ-HD100 Control Buttonski'vvri or iKAML")VARJAFiLKSLOWVARlARiii:FAST@ REWRewinds the recorded image back to the start position. ® VARIABL
IWJ-SX550B Matrix Switcher ControlConnections(1) Connect the MONITOR OUT connectors on the rear of the WJ-SX550B to the VIDEO IN connectors 1 to 4 on
(D MATRIX SWITCHER CONFIGURATIONSSelect and enter the same parameters for the following as set for the WJ-SX550 A/B, except the NT204 UNIT ADDRESS.OPE
(D LOGOUTLogs out of the WJ-SX550 control operation.© CAMERA SELECT (Bottom window panel)To select a camera (CAMERA 1 to 128) connected to the WJ-SX5
IWJ-DR200 AV Disc Recorder ControlConnectionsRandom Input Selection Mode(1) Connect CAMERA 1 and 2 to the VIDEO IN 1 and 2 connectors on the rear of
© ALARM REC STANDBYTo toggle between enabling and disabling alarm recording on the WJ-DR200 AV Disc Recorder.@ INDEXTo search the disk for
WJ-FS309/FS316/FS409/FS416 Video Multiplexer ControlThe following description is based on the assumption that a WJ-FS416 is installed in the system.
i! J.W. -»*'Va it ^'~~-mY.7^- ...-77^...PAXTH-rWE>ET E L I . i^AT. AtrrO CL'jFE openI pieetoh” OFF|V...-.i00^ !lid.miij[ZJ
This window appears when "INPUT from FRAME SWITCHER" button is clicked.® FS CAMERA SELECTThese buttons select the input to the video mult
WJ-HD100 Digital Disk Recorder Control• Connections1. Connect MONITOR OUT on the rear of the WJ-HD100 to AUX IN on the WJ-NT204 with a BNC attached c
® Mode DIP Switch [MODE]The default setting is marked with *.After changing the DIP switch, make sure to turn OFF the power switch once and then turn
© CAMERA SELECTThese buttons select the input image supplied to VIDEO 1-4 on the WJ-NT204 transmitter. The selected image appears in the Ima
This is a system example that the WJ-NT204 transmitter has 4 of directly connected combination cameras while it has 12 of combination cameras connecte
• Control OperationType in the location bar http://192.168.010/ . The 192.168.010 in the URL may vary depending on the WJ-NT204 setti
gssxnsi |::>j|jcfc:;T>^;,:::^V^::^^:^^ ^ jfe -0 '! ‘ij^' i;:® WJ-NT204 CONTROL PANELSwitches the whole of the window back to that of
This is a system exampie that the WJ-NT204 transmitter has none of directiy connected combination cameras whiie it has combination cameras connected
4. In the SERIAL PORT SETUP window, click the Unit Address SETUP page for AUX SYSTEMS to open the PS.Data Unit Address SETUP window.In the window, ty
(z) REWThe WJ-HD500 enters the fast reverse playback five times speed than the normal when this button is clicked in the normal playback,(8) RE
PS Data System Control (WJ-FS416, WJ-MP204s and WJ-HD100)This is a system example empioying a WJ*FS416 (or FS409/FS316/FS309 instead), four WJ-MP204
4. In the SERIAL PORT SETUP window, click the Unit Address SETUP page for AUX SYSTEMS to open the PS.Data Unit Address SETUP window.In the window, ty
(2) EL ZOOMOpens the EL ZOOM panel on the bottom center of the window while + sign is displayed in the Image Display representing the center of the ar
Rear View@ Video Input [VIDEO IN 1,2, 3, 4]Connect a maximum of four Panasonic’s Combination Cameras in the Remote site where the unit is s
Ф Unit/System SELECTIONThis selection changes the Control Operation window to that of the selected unit while connmunicating with the un
SONTENirS UPiOADContents upload to the WJ-NT204 transmitter can be made using a File Transfer Protocol (FTP), A single PC is allowed to upload at a
Image display, camera operation, and alarm image display can be effected on the WWW browser by means of commands described in the HT
Camera Operation• CGI functions related to camera operationThe WV-CS854 (optional) can be operated by using the following commands.The following com
HTML Sample File [mainpanel1.html]<HTML><HEAD><TITLEx/TITLE></HEAD><BODY BGCOLOR="#FFFFCC"><CENTER><!
HTML Sample File 2 [camctrl.html]<HTML><HEAD><TITLE><n'ITLE></HEAD><BODY BGCOLOR="#FFFFCC"><CENT
</TR><^ABLE></CENTER></BODY></HTML><^D><FORM ACT[0N=7cgi-bin/camctrr METHOD=POST><INPUT TYPE="hidden
Substitute Character Strings in HTTP ServerParameters can be described in HTML files by means of substitute characters as described below.• Ordinary
m %™iIIBLESHOOflNG[Troubleshooting in the system using WJ-NT204 Transmitter/Receiver]138SymptomsNo power is suppliedThe Network Interface Uni
SymptomsCheck itemsBad communication caused by noise19. Is there any possibility that the unit is disturbed by insufficient grounding or lack of cable
Controller Port [REMOTE]Connect with a Remote Controller WV-CU20 that only operates the unit. Connection cable is a 6-conductor modular
SymptomsCheck itemsCombination Camera Control failure47. Is the camera connected to the AUX IN terminal?If Yes, change the connection to VIDEO IN 1 to
Prior to having the unit repaired, check the following items. [Troubleshooting in the system using a WWW browser]SymptomsCheck itemsNo access from the
SPEGIFICATIONSjGeneralPower supply:Power consumption:Weight:Dimensions:Working temperature range:Working humidity range: Applicable line: Communicatio
STANDARDateESSQRIESiUtility Software (contained in the FD)...1Switch protector ...
APPENDllDefault SettingsThe default settings in the menus and DIP switch positions are shown below. The settings in the menus will return to the defau
• Rear DIP Switch Default SettingThe default positions are rinarked with *,Bit#OFFONFunction/Note1 Open* TerminateTermination on Transparent Receiving
Sensor OperationThe transmitter unit has 8 sensor inputs. The unit lets the camera direct to the preset position as an input is supplied while it in
LEVEL Type Input Remote SiteSensor In 1 :Sensor In 2 :Sensor In 3:Alarm Call:View Point Change; Communication : Disconnection Timer:Control SiteAlar
Panasonic Security and Digital Imaging Company A Division of Matsushita Electric Corporation of America Executive Office: One Panasonic Way 3E-7, Seca
WV-CU20 Remote Controller (Option)@ One-touch Dial Buttons [ONE TOUCH DIAL, 1 - 5]These buttons are used to call the destinations preset to the but
Escape Button [ESC]This button is used to escape and execute the currently highlighted setting on the setup menu. The monitor screen will then
MmThe following installations should be made by qualified service personnel or system installers and should conform to all local codes.For permanetly
Mounting in the Rack-CautionDo not block the ventilation opening or slots on the cover \which prevent the appliance from overheating.Always keep the t
On the Remote Site (Transmitter)Procure cables and connectors locally, when they are not supplied as standard accessories. For details on connection
IMPORTANT SAFETY INSTRUCTIONS1) Read these instructions.2) Keep these instructions.3) Heed all warnings.4) Follow all instructions.5) Do not use
When the site contains Data Multiplex Units, connect these units with cameras as shown. Connect among the units, from SPOT IN to SPOT OUT, from VS/VD
When the site contains the Video Muitiplexer, connect it with cameras as shown. More connections are needed from MULTI SCREEN OUT to
When the site contains a System 550 Matrix Switcher, connect it with cameras as shown. Connect the VÌDEO OUT on the MATRIX SWITCHER WJ-SX550 A/B with
Monitor terminals are used mainly for maintenance purposes on the Remote site. Connect the MON/SPOT terminal to VIDEO IN on the monitor with
• Control Device Connection on the Remote Site1. SENSOR INH'RIGGER OUT ConnectionsTwo connection examples are shown in this page, but there m
<Second example>In the second example there are 8 sensors relayed to a Video Multiplexer. The Video Multiplexer will enter the
Sensor In Trigger Out SpecificationsPin# Name Specification/Note1 GND2TRIGGER OUT 7 Open Collector Output. Low Active, Hold Time=300 ms, Controllable
The signal inputs entering the parallel inputs 1-8 on the control site are output to the parallel outputs 1-8 on the remote site. (Similarly, t
Parallel In/Out SpecificationsPin# NameSpecification/Note1 GND2Clock Adjust InConnect an Open Collector or non-voltage make-contact. Low Active (<0
Connect the 10/100BASE-T terminal to an Ethernet with a 10BASE-T or 100BASE-TX cable.Connect the RS-485 DATA PORT to other PS'Data equipment with
Caution:Before attempting to connect or operate this product, please read the label on the bottom.ACAUTIONRISK OF ELECTRIC SHOCK DO NOT OPENÎCAUTION:
• DIP Switch Setting on the Remote SiteSee the manual included in the peripheral equipment for more information on DIP switch settings.4. Dat
On the Control Site (Receiver)Connections on the Control site is outlined below in the figure.1. MONITOR ConnectionConnect the MON/SPOT terminal to
i DIP Switch Setting on the Control Site1. Set the WJ-NT204 Rear DIP Switch as follows. This setting applies when connecting with PS’Data devic
I Prior to SetupTurning On the Power. Confirm that the cameras and peripherals are connected correctly and securely.Turn on the power switches of all
Buttons Used for the SetupNumeric buttons-Escape button • Menu buttonCentioWer WV-CU2D□ 0SWITCHaVIDEO0AlUACK0□cxkck□□ [3 Q El□ E]WSET0 0000SET0□RFDU
Setup MenusAs shown below, tens of menus are provided to make setups as minute and convenient as possible.000 TOP menu-— 200 RECEIVING REGIr300 DIRE
100 CONFIGURATIONThis menu lets you set the operating mode and IP address in the network.1. Press the MENU button on the Remote Controller to open t
200 RECEIVING REGI.In this menu you can set up parameters related to the call reception mode.200 RECEZVIHO REQI.210 RECEIVIHG RE6I.1220 CALLING IP ADD
300 DIRECTORY DIALING REGI.3. Enter the IP address with the numeric buttons.IP addresses and titles are registered in the directory for Quic
320 ONE TOUCH DIALING REGI.The five ONE TOUCH DIAL buttons on the Remote Controller can be assigned the start point of sequential dial
CONTENTSPREFACE ... 5FEATURES...
400 SETUPEight of fundamentals are set up for the system.The menus 430, 460 and 470 will be replaced with dashed lines when the unit is set to a rec
3, Move the cursor to DATA BITS, then select a bit length with the or ► button.The default setting is 8.8: 8 bits 7: 7 bits4800: 4800 bps (bit per se
7. Move the cursor to ALARM area, and select either ON or OFF with the or ► button, then press the ENTER, The SENSOR IN terminals #1 through #8 on th
452 ON_SCREEN DISPLAYYou can set the display contents in this menu.452 OH-SCREEN DISPLAYVIDEOINPUT DISP.:ON OFFTITLE DISP. :ON OFFCLOCKDISP. :ONOFFTIi
This selection defines the sensor signal reception to the unit, and applies for all 8 sensor inputs. Consult the sensor on the output signal
2. Move the cursor to an input number and select ENABLE or DISABLE with the or ► button. The default setting is ENABLE.ENABLE; The un
4. Move the cursor to FUNCTION LOCK and select either ON or OFF with the or ► button. This setup is applied only to the receiver. The defau
500 REMOTE CONTROL/SETUP (Receiver only)Some of the Remote site setups can be changed from the Control site during communication in order for
600 MAINTENANCEA variety of maintenance menus can be used in both the Control and Remote sites. Menu window changes depending on the site
620 REMOTE CLOCK SETUP (Receiver during Communication)This menu enables the Control site to adjust the transmitter’s clock during communication.1, Op
The Network Interiace Unit WJ-NT204 is the key devices for a remote surveillance system. The unit works as an HTTP server and transmi
1. open the 642 CALUNG LOG menu.r\642CALLIHO LOG 1/1678 JAM.03 16:00 L DISC192.168. 0. 1477JAN.02 21:00CALLING192.168. 0. 1476 JAN.02 18:00 R DISCRece
680 MODE DISP (display) [In Communication Only]Transmission and reception mode for audio and video can be dispiayed in the communication status. Confi
700 REMOTE SETUP EDIT (Receiver in Communication)This menu lets the Control site (receiver) pull out the Remote site's (transmitter)
8. Press the ESC again. The upload dialog appears. UPLOAD? (LOCAL TO REMOTE) YES HOSELECT EHT:EXEC ESC:CLEAR9, Move the cursor to YES or NO with the
This section details about operations made in the control site where a WJ-NT204 Network Interface Unit is installed as a receiver. For
• Dialog ScreenThere are several dialogs that appear during normal operations: YES/NO inquiry, etc. The major operations are explained on th
During communication, the CONNECT indicator will illuminate.POWCF1a«я и П»ю VOI dSiSiì tuTTi ccitfiXCT taON«OFF*О a О aL0*i* HlChT-J5, To terminate
4. To terminate the call, hold down the DIAL button for 2seconds. The dialog changes to "LINE TERMINATED".2. Press a one-touch dial button.
1. Press the DIAL button.The DIRECT DIAL dialog appears.4. To terminate the call, hold down the DIAL button for 2seconds. The dialog changes to "
2. Enter "ООО" with the numeric button, and press the ENTER, then press the CALL. The dialog appears. Another way to start t
WiSSPPS-:Refer alt work related to the installation of this product to qualified service personnel or system installers.Do not attempt to disassemble
Alarm call receptionThe ALARM DIAL dialog appears when the unit accepts an alarm call.1. Press the ALM ACK button to display images sent from the al
• MuteMuting is available when audio is unnecessary.1. Press the MUTE button. The Control site stops sending audio while the monitor displays th
A dialog saying “RECEIVE A CALL?" may appear on the Control site monitor while the site is in communication with a Remote site. This ind
Remote Site Setup OperationsBesides in the setup menus displayed on the Remote site, the following parameters can be operated from the Control site
PC SETUP & OPERATION65
Computer RequirementsOS: Windows98, 98SE/Windows NT4.0/Windows2000 or Windows ME Note: Windows95 are not applicable to this system.WWW browser:Interne
• PC SetupGraphics on the right column are from WindowsMe,The factory default settings of the WJ-NT204 are as follows;IP address192.168.0.10Netmask255
3. Restart the PC.If your browser is Internet Explorer, proceed as follows.(1) Start Internet Explorer.(2) Click the Tool menu, then Internet Optio
WJ-NT204 SetupFirst, it is necessary to set an IP address for the WJ-NT204 according to the operating environment. Consult your net
There are some system forms depending on the number of the sites, and the network routings. Basic Connection with WJ-NT204 ReceiverIn the basic conne
There are two image transmission/reception methods to monitor remote places on the WWW browser: the H.261 and JPEG. One mode must be selected at the
About Operation WindowsAn operation window is made up of four major frames with the html description as follows.iW- X*** ^.mVI ii g"31‘*‘Main
Operation Modeimage transmission is carried out as follows between the transmitter WJ-NT204 and the PC on the Control sites.• Random Input Selection
Image Quality Setup• Image ResolutionThe following 3 image resolutions (number of picture elements) are available. The higher the resolution is set,
• Image QualityThe following four innage qualities {compression ratios) are available. The lower the compression ratio is set, the better the
Main Page (without Camera Control)This page appears when a LEVEL 3 user made access, and the MODE SETUP is set as follows. MODE SETUP CAM CONTROL: OTH
Main Page (with Camera Controi)This page appears when a user authorized level 2 or higher made access, and the MODE SETUP is set as follows. MODE SETU
® IRISThese buttons control the iris of the lens mounted on the combination camera. Click a button as you may need. When you open or close the iris co
ALARM LIST WindowThe ALARM LIST appears when the ALARM LST button is clicked in the MAIN PAGE. The list stores and displays up to 100 alarm events i
SETUP RROCEDURÈS How to Read ADMINISTRATOR SETUP PAGEOn the Location bar, type http://192.168.0.10/hwsetup.html to display the ADMINISTRATOR
Basic Connection with PC Browser8Remote SiteControl SiteCombination Cameras {4)
(D HOSTTo set the address of the host that can be accessed without user authorization.® DATETTIMETo set the internal clock of the device.(D
MODE SETUPOn the ADMINISTRATOR SETUP PAGE, click the MODE SETUP button to display the MODE SETUP window.Select set Operation mode, image quality and
(?>»и Ot... ;л. ьа' ti ^ -Й*«а-»| »¡f*Hirtli'' .^- lJ ^Ыф//1аг1«01£1Л**ч1ьв1 WniШ0ШШЩ...Ol1 FFTTJKinX' ЦМАПТГАСЕЮ1
NETWORK SETUPOn the ADMINISTRATOR SETUP PAGE, dick the NETWORK button to display the NETWORK SETUP window.Select set IP address, netmask, and defaul
VIDEO SEQ/ALARM SETUPThe transmitter has 8 view points to trace them in order in the sequential video scan and transmit images to the Control site.
(D ALARM TYPEThis setting specifies the sensor (alarm) input reception whether to accept or ignore depending on the signal forms, and applie
SERIAL PORT SETUPOn the ADMINISTRATOR SETUP PAGE, dick the SERIAL PORT button to display the SERIAL PORT SETUP window Specify whether to use the RS-23
Clicking on the line indicated CD in the previous page displays the PS'Data Unit Address SETUP page.03EOES:j Ji^ ^Ap ^ S21 0 iMwv^l MMrS.Data Uni
USER SETUPOn the ADMINISTRATOR SETUP PAGE, click the USER button to display the USER SETUP window. Use this window to register or delete users.>
HOST SETUPOn the ADMINISTRATOR SETUP PAGE, click the HOST button to display the HOST SETUP window. Use this window to register or delete the HOST I
Multi-Site ConnectionThe Multi-site connection enables you to monitor the same image at a maximum of 4 Control sites. A Remote site can transmit ima
On the ADMINISTRATOR SETUP PAGE, dick the DATE/TIME button to display the CLOCK SETUP window. Use this window to adjust the internal clock of the devi
CAMERA SETUP MENUOn the ADMINISTRATOR SETUP PAGE, dick the CAMERA MENU button to display the CAMERA SETUP MENU window.The cameras (option) can be se
RECEIVING SETUPOn the ADMINISTRATOR SETUP PAGE, click the RECEIVING button to display the RECEIVING SETUP window.© RECEIVING MODE READY STATEThe def
DIRECTORY SETUPOn the ADMINISTRATOR SETUP PAGE, dick the DIRECTORY button to display the DIRECTORY SETUP window.Register IP addresses and names in t
ALARM DIALING TABLE SETUPOn the ADMINISTRATOR SETUP PAGE, click the ALARM TABLE button to display the ALARM TABLE SETUP window.® AUTOMATIC DISCONNEC
OTHERS SETUPOn thG ADMINISTRATOR SETUP PAGE, click the OTHERS button to display the OTHER SETUP window.95
Ф ONE-TOUCH DIALING REGISTRATIONThe five ONE TOUCH DIAL buttons on the Remote Controller can be assigned the start point of sequential dial (
MAINTENANCEMAINTENANCE INDEX FILE SELECT® WJ-SX550B CAMERA MENU SETUP PAGESetup is available for the cameras connected with the WJ-NT204 transmitt
WJ-SX550A/B CAMERA MENU SETUP PAGE...‘iMIMinNvMUIOIIlll3^**^ ':t4»‘"i ¡MODEEEniP3|^ T;nvoitKm i;i [V^EO SEO:! lALf^..._ii iSHOUFOItTi; jUjEl
WJ-FS616 MENU SETUP PAGEij't* 5*2i^*'*^^*»* i i- '" » ' ,-y-. % X-'-- / :iim' ^ .• ^i-mx(D MENU buttonsTh