Condensation Sensor – 3 controls in 1
Humidity – Countdown Timer – Manual On/Off
Control
Humidity Control – Automatically turns on
exhaust fan to control humidity
Countdown Timer – Manually turning the fan on
initiates a 30 minute countdown cycle
Manual On/Off Control – Push the switch for
manual fan operation
Includes matching wall plate
Condensation Sensor – 3 controls in 1
Humidity – Countdown Timer – Manual On/Off/
Light Control
Humidity Control – Automatically turns on exhaust
fan to control humidity
Countdown Timer – Manually turning the fan on
initiates a 30 minute countdown cycle
Manual On/Off Control – Push the switch for
manual fan operation
Includes matching wall plate
FV-WCCS1-W (White)
FV-WCCS1-A (Almond)
—FAN Only
FV-WCCS2-W (White)
FV-WCCS2-A (Almond)
—FAN/LIGHT
Product Specifications
Ground
Grounding
Feature
Blue Led Light When On
Amperage
15
Maximum Fan Load
1/8 hp or 3 Amps
Voltage
120 Volts
Terminations
6" Leads
Connections (Copper Wire Connections)
Use #14 or #12
Max Fluorescent Light Load
N/A
Standards and Classifications
UL/CSA Listed
Warranty
1 Year Limited
Product Specifications
Ground
Grounding
Feature
Blue Led Light When On
Amperage
15
Maximum Fan Load
1/8 hp or 3 Amps
Voltage
120 Volts C21
Connections (Copper Wire Connections)
Use #14 or #12
Max Fluorescent Light Load
400 Watt
Standards and Classifications
UL/CSA Listed
Warranty
1 Year Limited
Specification Submittal Data / Panasonic Ventilation Fan
WhisperControl
Panasonic Home and Environment Company
Division of Panasonic Corporation of North America
One Panasonic Way
Secaucus, NJ 07094
www.panasonic.com/building
For complete Installation Instructions visit
www.panasonic.com/building
Model Quantity Comments Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
VF11074SS-08
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - WhisperControl

Condensation Sensor – 3 controls in 1Humidity – Countdown Timer – Manual On/Off ControlHumidity Control – Automatically turns on exhaust fan to contro

Seite 2

Specification Submittal Data / Panasonic Ventilation FanWhisperControlPreset Countdown Delay Off TimerPreset for 10-20-30 or 60 minute intervalsFits si

Kommentare zu diesen Handbüchern

Keine Kommentare